An omnipolar switch with a contact opening distance of 3 mm or
higher should be provided for installation, enabling complete
disconnection under overvoltage category III conditions.
Products equipped with three-phase wiring (T) engines ALWAYS
require connection to 380-415V (or only 400V where required) three-
phase lines, or also 220-240V (or only 230V where required). Any
kind of modification shall be considered as product tampering and
shall nullify the relative warranty.
Caution
• In order to provide exhaust above the kitchen stove burners the hood must be installed in accordance with
the existing laws and by someone who is properly qualified to do so. Furthermore the installation must comply
with regulations regarding hoods designed for installation in kitchens or in other rooms where gas units, such
as stoves and water-heaters, are located. Most importantly, the room in which the hood is installed must have
an adequate air-inlet opening. If one does nor exist, an opening must be made and have the dimensions
indicated in the aforementioned specifications.
• This appliance must be installed to discharge into a single duct directly to the outside.
• Before installing the unit, try the draft of the exhalation duct.
Instructions for providing exhaust above kitchen stove burners
1) The ventilator must be turned on when cooking starts.
2) Leave the kitchen door open and close the window.This will ensure a single flow from other rooms to the
kitchen.
3) In order to eliminate residual odours and steam after cooking, leave ventilator running for a further 10-15
minutes.

Installation

÷
Fig. 4
14

Cleaning

÷
Fig. 15
18