Operating instructiOns
eSD (eLecTroSTATIc DIScHArge) proTecTIoN
Sensitive electronic components can be damaged by electrostatic discharge (please note the war-
nings on the packaging, or ask the manufacturer or supplier). This station can be integrated into a
ESD- protected workstation to protect these components.
The soldering station is fitted with a grounded ESD socket on the back. Here you can connect for e.g.
ESD bracelets or ESD mats.
TemperATUre SeTTINg
The temperature can be set between 200°c and 480°c.
There are two ways to set the temperature.
-
+
1. Using the
or
buttons:
+
● Pressing
button once the temperature will increase by 1°C.
+
● Holding
button the temperature setting will run upwards, until you release the button.
-
● Pressing
button once the temperature will decrease by 1°C.
-
● Holding button
the temperature setting will run downwards, until you release the button.
2. Direct input of desired temperature:
● Press
*
button for longer than 2 seconds. Hundreds digit will be flashing.
-
+
● Use
or
to select the desired value.
● Press
*
short. Tens digit will be flashing.
+
-
● Use
or
to select the desired value.
● Press
*
short. Ones digit will be flashing.
-
+
● Use
or
to select the desired value.
● Press
*
short. Desired temperature value will be taken.
28