5-2. Remote Amperage Switch
NOTICE - Arcing can damage switch. Do not
change Remote Amperage switch position
while power is on. Arcing inside switch can
damage contacts, causing switch to fail.
1

Remote Amperage Switch

Use switch to select way of controlling
amperage adjustment.
For front panel control, place switch in the
Panel position.
2
3
5
For remote control, place switch in the
Remote position and connect remote
amperage control to remote amperage
control receptacle (see Section 5-1). See
example.
2
Example: Combination Remote
Amperage Control
3
Set Remote Amperage Switch
4
Select Amperage Range
1
4
6
Max (100 A DC)
Min (30 A DC)
5
Select Maximum Amperage
6
Adjust Remote Amperage Control
In example:
Range Selected = 30 to 280 A DC
Maximum Amperage Selected = 100 A DC
Min = 30 A DC
Max = 100 A DC