6-2. Remote Amperage Switch

NOTICE − Arcing can damage switch. Do
not change Remote Amperage switch posi-
tion while power is on. Arcing inside switch
can damage contacts, causing switch to
fail.
1
Remote Amperage Switch
Use switch to select way of controlling am-
perage adjustment.
For front panel control, place switch in the
OM-2230 Page 22
2
3
4
5
Panel position.
For remote control, place switch in the Re-
mote position and connect remote amper-
age control to remote amperage control re-
ceptacle (see Section 6-1). See example.
2
Example: Combination Remote
Amperage Control
3
Set Remote Amperage Switch
4
Select Amperage Range
1
6
Max (100 A DC)
Min (30 A DC)
5
Select Maximum Amperage
6
Adjust Remote Amperage Control
In example:
Range Selected = 30 to 280 A DC
Maximum Amperage Selected = 100 A DC
Min = 30 A DC
Max = 100 A DC
Ref. 122 035-B