Remote Amperage Switch; Power Switch - Miller SRH-444 Mode D'emploi

Masquer les pouces Voir aussi pour SRH-444:
Table des Matières

Publicité

5-3. Remote Amperage Switch

Example: Combination Remote Amperage Control
Set Switch
Select Maximum Amperage

5-4. Power Switch

1
1
1
Y Arcing can damage switch.
Do not change Remote Am-
perage switch position while
power is on. Arcing inside
switch can damage con-
tacts, causing switch to fail.
1
Remote Amperage Switch
2
Remote Amperage Control
Use switch to select way of control-
ling amperage adjustment.
For front panel control, place switch
in the Panel position.
For remote control, place switch in
the Remote position and connect
remote amperage control to remote
amperage control receptacle (see
Section 4-11). See example below.
Select Amperage Range
In Example:
Range Selected = 30 to 280 A DC
Maximum Amperage Selected = 100 A DC
Min = 30 A DC
Max = 100 A DC
2
Max (100 A DC)
Min (30 A DC)
Adjust Remote Control
1
Power Switch
Use switch to turn unit On and Off.
OM-2230 Page 21

Publicité

Table des Matières
loading