WARNING
!
This appliance must be installed in a solid-fuel burning fi replace with a working fl ue and constructed of non-
combustible material.
The appliance and gas logs function as a system. If the appliance is not drafting properly and spilling into the room
(check with a match or a smoke stick), reposition the damper clamp until a positive draft is obtained by opening
the damper. If negative pressure in home prevents having a positive draft, consult an air quality specialist.
2.1

gas piping

WARNING
!
Do not connect either the wall switch, thermostat or gas valve to electricity (110 volts).
This appliance must be isolated from the gas supply piping system by closing the individual manual shut off valve
during any pressure testing of the gas supply piping system at test pressure equal to or less than ½ psi (3.5 kPa)
A.
Centre the appliance in the fi replace opening, making
sure the appliance has enough room behind it for the gas
line to run behind the log set under the log support.
B.
Route the gas line and sizing using piping ½" diameter or
greater to allow the full volume of gas to the appliance.
The routing of the gas line has to be done to local and /
or national codes.
C.
When rigid pipe is used an ANSI approved manual shut
off and a union must be installed upstream within the
appliance cavity.
D.
To ensure the appliance operates reliably, install a
sediment trap upstream of the appliance within the
structures of the piping system.
E.
When using propane, a regulator must be used between
the tank and the outside wall of the house to ensure the line pressure does not exceed 14" w.c.
F.
Check gas connections with a gas detection device to test for leaks in the system. Soapy water mixture
can also be used to check for leaks.
G.
Once all the gas connections are tested for leaks, start the appliance. Follow the lighting instructions to
ensure the appliance is working properly before fi nishing.

2.0 installation

installation
Regulator
Union
Appliance
3" (76.3mm)
Sediment
Trap
W415-1071 / F / 11.16.19
EN
Manual
Shut-Off
Valve
Appliance
Wall
Shut-Off
Key