Troubleshooting - Napoleon Fiberglow Série Manuel D'installation Et D'opération

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

WARNING
!
Turn off gas and electrical power before servicing the appliance.
Appliance may be hot. Do not service until appliance has cooled.
Do not use abrasive cleaners
Do not paint pilot assembly.
symptom
Pilot will not light and
Battery.
/ or makes noise
Wiring.
with no spark at pilot
burner.
Loose connection.
IGNITOR
(SPARK)
Module.
SENSOR
Igniter spark gap is incorrect.
Electrode.
PILOT TUBE
A shorted or loose
connection.
Improper switch wiring.
Module is not grounded.
Pilot sparks but will
Gas supply.
not light.
Out of propane gas.
Carbon is being
Air shutter has become
deposited on glass,
blocked.
logs, rocks, media or
Flame is impinging on the
combustion cham-
glass, logs, rocks, media or
ber surfaces.
combustion chamber.
problem
-
Check batteries.
-
Verify the wire for the sensor and the wire for the ignitor are
connected to the correct terminals (not reversed) on the
module. NOTE: Sensor has 3/16" (4.8mm) connection
and ignitor has 1/8" (3.2mm)connection.
-
Verify no loose connections, electrical shorts in the wiring or
ground out to any metal object.
-
Turn the ON/OFF switch to the "OFF" position. Remove the
igniter wire from the module. Place the ON/OFF switch to the
"ON" position. Hold a grounded wire about 3/16" (4.8mm)
away from the ignitor (spark) terminal on the module. If no
spark the ignitor terminal module must be replaced. If there is
a spark the ignitor terminal is fi ne.
-
Spark gap of the ignitor to the pilot should be 1/8" (3.2mm).
-
Inspect pilot assembly for a shorted wire or cracked insulator
around the electrode.
-
Remove and reinstall the wiring harness that plugs into the
module. Remove and verify continuity of each wire in wiring
harness.
-
Troubleshoot the system with the simplest ON/OFF switch.
-
Verify the valve and pilot assemblies are properly grounded to
the metal chassis of the appliance or log set.
-
Verify that the incoming gas line ball valve is "Open". Verify
that the inlet pressure reading is within acceptable limits, inlet
pressures must not exceed 14" W.C.(34.9mb)
-
Fill the tank.
-
Ensure air shutter opening is free of lint or other obstrucitons.
-
Check that the glass, logs, rocks or media are correctly
positioned.
-
Open air shutter to increase the primary air.
-
Check the input rate: check the manifold pressure and orifi ce
size as specifi ed in the instructions.
9.0

troubleshooting

troubleshooting
test solution
W415-1071 / F / 11.16.19
EN
21

Publicité

Table des Matières
loading

Table des Matières