FHMA 604 3G DC / FHMA 755 4G DC/DCL / FHMA 905 4G DCL / FHSM 604 3G DC
Connection to gas supply
X
Connect the appliance to the gas supply in
compliance with the current regulations,
only after making sure it is arranged for the
type of gas to be used. Otherwise, carry out
the operations described in the paragraph
„Replacing injectors".
Z
For liquid gas use pressure regulators
complying with the current regulations.
Connection to the gas supply can be made
in two ways:
A. Connect the gas hob using a 12 mm diameter
rigid copper pipe (3). To ensure a good seal, use
the elastomer gasket supplied as an accessory (1).
B. Connect the hob using a continuous-surface
flexible steel tube (2). Also in this case, to
ensure a good seal use the gasket supplied as
an accessory (1). The maximum length of the
hose is 2 linear metres.
Important: if a stainless steel hose is used,
it must be installed so as not to touch
any mobile part of the furniture. It must
pass through an area where there are no
obstructions and where it is possible to inspect
it on all its length.
X
After connection to the gas supply light up
the burners and turn the knobs from max
position to minimum position to check
flame stability.
X
After carrying out the connection use soapy
water to check for any leaks.
For United Kingdom, Northern Ireland and
Republic of Ireland.
FHSM 604 4G / FHSM 755 4G DC / FHSM 905 4G DCL
1
1
2
3
1
2
3

Electrical connection

The FRANKE cooking hob comes with a 3-core
power cable with free terminals.
X
Ensure the following:
The characteristics of your household
electrical power supply (voltage, maximum
output and current) are compatible with
those of your FRANKE hob.
The plug and the socket can be easily
reached and are positioned so that no
live part is accessible when inserting or
removing the plug.
A 3 x 0.75 mm2 H05RR-F type cable
for completely gas hobs is used when
replacing the power cable.
The terminals of two appliances are not
connected to the same plug.
The polarities of the free terminals
(Blue = Neutral = (1) /Yellow and Green
= Earth =(2) / Brown = Live = (3)) are
respected.
1
2
3
L
Adjustment to different types of gas
WARNING: This operation must be performed
by a qualified technician.
Minimum flame adjustment
X
Remove the knob.
X
Insert the screwdriver between the
gasket and the cover until it reaches the
adjustment screw.
X
Adjust the minimum flame by turning the
screw clockwise to decrease the flame
and anticlockwise to increase it.
The screwdriver for adjustment is supplied
with the accessories.