Q UI C KIE PU LS E
IMPORTANT ICONS AND MESSAGES (color and advanced)
41
Latched
When the control system is operating in a Latched condition this symbol will be displayed.
42
Inhibit
If the speed of the wheelchair is being limited; for example, by a tilted seat, then this orange symbol
will be displayed. If the wheelchair is being inhibited from driving, then this red symbol will be flash-
ing.
MODE SCREENS:
43
Actuator (Seating) Mode
Displays the sections of the chair currently selected for movement, the name given to the selection
and a direction arrow showing what sort of movement is available.
44
Speed Adjust
When Speed Adjust Mode is entered, this screen will be displayed momentarily.
Color Joystick Message Window
The RNET displays warning icons and informational messages, in a dedicated message window.
Advanced Joystick Message Window
The RNET displays warning icons and informational messages, in a dedicated message window.
47
Restart
When the control system requires a reboot; for example, after a module re-configuration, this green
symbol will be flashed.
E-Stop
48
If the External Profile Switch is activated during drive, or actuator operation, this red symbol will be
displayed.
49
Joystick Displaced
If you operate the Joystick before or just after you switch the control system on, the screen will
flash the joystick displaced screen.
You must release and center the joystick to resume normal operation. If you do not release the joy-
stick within five seconds the wheelchair will not be able to move, even if you release the joystick
and operate it again. The screen will display a diagnostic screen at this time. You can reset this condi-
tion by switching the control system off and on again.
50
Control System Locked
The control system can be locked in one of two ways. Either using a sequence of deflections and
presses with the Joystick, or with a physical key. How the control system is locked depends on how
the wheelchair manufacturer has programmed it. Refer to the R-Net technical manual SK77981-
Programming chapter for more details.
51
MOMENTARY SCREENS
If the momentary screens are programmed to be displayed, then pressing the Speed or Profile
Buttons will display screens such as this.
52
DIAGNOSTIC SCREEN
When the control system safety circuits have operated and the control system has been prevented
from moving the wheelchair, a diagnostics screen will be displayed. This indicates a system trip, i.e. the
RNET has detected a problem somewhere in the wheelchair's electrical system.