Assembly

Selecting a location

Install control panels in a location that is protected from mois-
ture and humidity.
CP classic control panel
– Drill hole with diameter of 55 mm.
– Attention: Maximum length of connector cable 10 m.
– Attach plug (3) of the connector cable (2) to control panel (1).
– Clamp connector cable (2) in cable duct of control panel.
– Route connector cable (2) to heating system and plug in.
– Ensure that all connectors are engaged.
– Secure control panel with 4 screws (4).
– Fit cover frame (10) with side parts (11).
m
5 5
Ø
2
3
m
4
3
1
11
10
11
CP classic control panel and
CP E classic power selector switch
– Drill hole with a diameter of 55 mm for each device
( distance between hole centres 66 mm).
– Connect control panel (1) and power selector switch (5)
using control panel connecting cable (6).
– Attention: Maximum length of connector cable 10 m.
– Attach plug (3) of connector cable (2) to power selector
switch (5). Clamp cables (2 + 6) into control panel cable
guides.
– Route connector cable (2) to heating system and plug in.
– Ensure that all connectors are engaged.
– Secure each control panel with 4 screws (4).
– Fit cover frame (10) with side parts (11).
5 5
6
Ø
2
3
3
m
m
1
4
5
11
4
10
11 10