Installation; Cabinet Requirements; Installation Procedure; Electrical Connection - Franke SMART PLUS SGP 62 M /F Manuel D'installation Et Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 37
SGP 62 M _/F / SMP 62 M _/F / SMP 66 M _/F / CF 65 M _/F

INSTALLATION

Important: Installation (Fig. 4) must be carried
out in compliance with current standards and
regulations.

Cabinet requirements

9 For fitted units, the components (plastic
materials and veneered wood) must be
assembled with heat-resistant adhesives
(min. 100 °C):
unsuitable materials and adhesives
can result in warping and ungluing.
9 The cabinet must allow sufficient room for
the electrical connections.
9 The cabinet in which the oven is fitted
must be strong enough to take the weight
of the equipment.
Z
X
The oven must be securely installed in
the recess.
Z
X
The oven can be installed in a column
cabinet or under the top of a modular
unit, provided sufficient ventilation is
guaranteed.

Installation procedure

Fit the appliance in the compartment; fix the
oven to the cabinet with the 4 screws and the
4 bushings provided, using the holes prepared
in the side panels (Fig. 5a).
Note: (Fig. 5b)
If the oven is to be fitted under a cooktop,
firstly turn the top connection (R) to the right or
left so that the oven fits properly (Fig. 5b).

Electrical connection

Franke ovens are supplied with a three-pole
power cable with free terminals.
If the oven is permanently connected to the
power supply, install a device that ensures
disconnection from the power supply, with
a contact opening distance (at least 3 mm)
enabling complete disconnection in category III
overvoltage conditions.
Make sure:
9 The plug and socket are suitable for a
16 A current.
9 Both can be easily reached and are
positioned so that no live part is accessible
when inserting or removing the plug.
9 The plug can be easily inserted.
9 The oven does not rest against the plug
when installed in the cabinet.
9 The terminals of two appliances are not
connected to the same plug.
9 A 3 x 1.5 mm² cable type H05VV-F is used
when replacing the power cable.
9 Make sure you observe the polarities of the
free terminals.
BLUE
YELLOW-GREEN
BROWN
L
Note:
Make sure the characteristics of the household
electrical system (voltage, maximum power
and current) are compatible with those of your
Franke oven.
The mains frequency is established at
switching on.
– 7 –
Brown = Live
Blue = Neutral
Yellow/Green = Earth