Logic
Definition
Configuration of
EXPI2 input
on input-output
EXPI2
expansion board.
1-3
Configuration of
EXPO2 output
on input-output
EXPO1
expansion board
4-5
Configuration of
EXPO2 output
on input-output
EXPO2
expansion board
6-7
INSTALLATION MANUAL
Cross
out
Default
setting
used
0
Input configured as Start E command.
1
Input configured as Start I command.
2
Input configured as Open command.
3
Input configured as Close command.
4
Input configured as Ped command.
0
5
Input configured as Timer command.
6
Input configured as Timer Pedestrian command.
7
Input configured as Phot (photocell) safety.
8
Input configured as Phot op safety (photocell active during opening only).
9
Input configured as Phot cl safety (photocell active during closing only).
10
Input configured as Bar safety (safety edge).
1
Output configured as SCA (gate open light).
2
Output configured as Courtesy Light command.
3
Output configured as Zone Light command.
1
4
Output configured as Stair Light.
5
Output configured as Alarm.
6
Output configured as Flashing light.
7
Output configured as Latch.
9
8
Output configured as Magnetic lock.
9
Output configured as Maintenance.
10
Output configured as Flashing Light and Maintenance.
Optional extras
LEO B CBB 3 400 W 01-