MENU 04 – Select language
With this selection it is possible to set the desired language from those available.
MENU 05 – Standby mode
By selecting ON in STANDBY mode the corresponding symbol on the display lights up and the stove shuts down
automatically when the room temperature T has reached the set value (Tset + ΔT) for a given time.
The next restart in automatic will be possible only when the room temperature falls below the set value by a few
degrees and precisely (Tset - ΔT) where ΔT default = 2°C.
By selecting OFF the insert activates the modulation function but not the STANDBY mode. Therefore when the
temperature exceeds the set value, the insert operates at minimum power.
MENU 06 – Buzzer mode
With this selection it is possible to activate or deactivate the insert acoustic signals for alarms and for pressing
buttons on the remote control.
MENU 07 – Initial load
Allows the preloading of pellets for a given time. This function can only be activated when the insert is off and is
used if the auger is empty due to no more pellets. It is started with button P1 and stops with button P3.
MENU 08 – Stove/insert status
This selection is reserved for the COLA service center authorized technician.
MENU 09 – Technician settings
This selection is reserved for the COLA service center authorized technician.
Modification of the technical parameters of menu 09 must be done by authorized and competent
personnel; any random changes made can cause serious damage for which COLA declines any liability.
MENU 10 – Installer settings
This selection is reserved for the qualified installer and/or COLA service center authorized technician.
–
MENU 11
MAGIC CLEANING function : select this function while the machine is working will force BRAZIER
CLEANING. When OFF, activating this function will put the machine into FINAL CLEANING. From the state of
FINAL CLEANING, if this button is pressed again it will discharge the FINAL CLEANING timer thus leaving intact
the safety checks on the flue gas temperature.
MENU 12 – ACTIVE FUNCTIONS - OFF - the stove remains on the configured SET.
TURBO function: like the QUICK function with the difference that the heater does not modulate P1 power with set
ambient or set water satisfied but modulates only in the flue gas safety condition.
QUICK function: forces the machine power onto P5, saving the previous set power. Ventilation, too, if present, is
forced onto AUTOMATIC (so maximum ventilation); saving the previous ventilation value. When pressed with the
comfort function activated, it restores power and ventilation to the previous saved value. With set ambient or set
water satisfied the heater modulates P1 power together with ventilation.
COMFORT function: forces power and ventilation onto P1. Deactivating this function will take the power and
ventilation to the value prior to activation.
This function observes and performs STANDBY.
4.2.5
Replacing the battery
The remote control is powered by tree batteries located in the back of the device. For insertion and possible
replacement, proceed as follows:
- Open the cover on the back of the remote control;
- Replace the AAA 1.5 V batteries, respecting the
polarity;
- Close the remote control
- Keep the remote control away from direct heat sources and water.
- The battery of the remote control must be replaced and disposed of in a safe way,
respecting the local regulations;
Cover
44