Extraction capacity
max. 1700 m�/h (1000 CFM)
Fan speed
2800 rpm
Noise level
79 dB(A) according to ISO 3746
- with silencer SAS-315
70 dB(A) according to ISO 3746
Electrical data
Power consumption
2,2 kW (3 HP)
Available connection
- 400V/3ph/50Hz
voltages
Switch box
24V
Motor design
IEC
Energy efficiency
IE3 / premium
Mains cord
not included
Plug
not included
Welding fume class
W3
according to ISO 15012-1:2013
1.4.1
Dimensions
Refer to Fig. I on page 52.
1.5
Working range
Refer to Fig. II on page 52.
1.6
Ambient and process conditions
Process temperature:
- min.
- nom.
- max.
Max. relative humidity
Suitable for outdoor use
1.7
Transport of the unit
You cannot hold the manufacturer liable for any transportation
damage after delivery of the product.
- Handle the filter unit and the accompanying extraction arms
with care.
- Completely dismount the extraction arms before transport.
Dismount the arms by executing the mounting procedure in
reverse order. Subsequently the filter unit and the arms can
be transported on a pallet in the original packing.
- To prevent damage, make sure that the filter unit and the
arms cannot shift on the pallet.
2

PRODUCT DESCRiPTiON

2.1
Components
The product consists of the following main components and
elements:
Fig. 2.1
A fan + motor
B
HEPA filter cassette
C
pre filter cassette
D extraction arm (2) (shown: hose tube arm)
E
switch box
F
shut-off damper
0000111692/150418/A DualGo
5°C (41°F)
20°C (68°F)
70°C (158°F)
90%
no
Fig. 2.1 Main components and elements
2.2
Operation
The DualGo works in accordance with the recirculation
principle. Welding fume is extracted through the hood of the
connected extraction arm by the built-in fan. The polluted air
passes the pre filter cassette and is cleaned by the HEPA filter
cassette.
The cleaned air is returned in the workshop through the outlet
of the fan.
2.2.1
Indication of filter replacement
The DualGo has a service indicator that monitors the airflow. It
gives an acoustic signal to replace the filter(s).
3

SAFETy iNSTRUCTiONS

General
The manufacturer does not accept any liability for damage to
the product or personal injury caused by ignoring of the safety
instructions in this manual, or by negligence during
installation, use, maintenance, and repair of the product
mentioned on the cover of this document and any
corresponding accessories.
Specific working conditions or used accessories may require
additional safety instructions. Immediately contact your
supplier if you detect a potential danger when using the
product.
The user of the product is always fully responsible for
observing the local safety instructions and regulations.
Observe all applicable safety instructions and
regulations.
User manual
- Everyone working on or with the product, must be familiar
with the contents of this manual and must strictly observe
the instructions therein. The management should instruct the
personnel in accordance with the manual and observe all
instructions and directions given.
- Do not change the order of the steps to perform.
- Keep the manual with the product.
A
B
C
D
E
F
EN - 4

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Dualgoplus

Table des Matières