pREFACE
Using this manual
This manual is intended to be used as a work reference for a
professional/licensed electrician, well-trained and authorised
users to safely install, use, maintain and repair the product
mentioned on the cover of this document.
pictograms and symbols
The following pictograms and symbols are used in this manual:
ATTENTIoN
A remark with additional information for the user.
A remark brings possible problems to the user's
attention.
CAUTIoN!
Procedures, if not carried out with the necessary
caution, could damage the product, the workshop or
the environment.
WARNINg!
Procedures which, if not carried out with the
necessary caution, may damage the product or
cause serious personal injury.
WARNINg!
Denotes risk of electric shock.
WARNINg!
Important warning to prevent fire.
Text indicators
Listings indicated by "-" (hyphen) concern enumerations.
Listings indicated by "●" (bullet point) describe steps to
perform.
Service and technical support
For information about specific adjustments, maintenance or
repair jobs which are not dealt with in this manual, please
contact the supplier of the product.
Make sure you have the following specifications at hand:
- product name
- serial number
These data can be found on the identification plate.
1
INTRoDUCTIoN
1.1
Identification of the product
The identification plate is attached to the side of the SA-24
control box. It contains, among other things, the following
data:
- product name
- serial number
- supply voltage and frequency
1.2
general description
The SA-24 enables you to operate an extraction fan and
halogen lamp cartridge from a switch on the extractor hood.
The starter is wall-mounted. Power is connected to the
extraction fan via the starter. It has a built-in 5 Hp contactor,
which operates the fan via a control voltage of 24V. A halogen
lamp cartridge in the extractor hood may also be connected to
the 24V transformer of the starter.
1.3
options and accessories
The halogen lamp cartridge can be ordered as an accessory.
0000101012/070114/B SA-24
1.4
Technical specifications
Intended for use at one work station with one extractor and
one fan.
Power supply: 115/208/230/400/480/600V.
Transformer: 24V/30VA for one halogen lamp cartridge
(HL-20/24). The transformer also controls the built-in
contactor.
Table for choice of motor overload for
1.4.1
SA-24 50Hz
product
motor kW
0,37
FUA-1300
0,37
FUA-1300
0,55
FUA-1800
0,75
FUA-2100
0,75
FUA-2100
1,1
FUA-3000
2,2
FUA-4700
1.4.2
SA-24 60Hz
Not applicable; thermal overload included in scope of supply.
1.5
Ambient conditions
Min. operating temperature
Nom. operating temperature
Max. operating temperature
Max. relative humidity
2
SAFETy
general
The manufacturer does not accept any liability for damage to
the product or personal injury caused by ignoring the safety
instructions in this manual, or by negligence during
installation, use, maintenance, and repair of the product
mentioned on the cover of this document and any
corresponding accessories. Specific working conditions or used
accessories may require additional safety instructions.
Immediately contact your supplier if you detect a potential
danger when using the product.
The user of the product is always fully responsible for
observing the local safety instructions and regulations.
User manual
- Everyone working on or with the product must be familiar
with the contents of this manual and must strictly observe
the instructions therein. The management should instruct the
personnel in accordance with the manual and observe all
instructions and directions given.
- Never change the order of the steps to perform.
- Always keep the manual with the product.
Pictograms and instructions on the product (if
present)
- The pictograms, warning and instructions attached to the
product are part of the safety features. They must not be
covered or removed and must be present and legible during
the entire life of the product.
- Immediately replace or repair damaged or illegible
pictograms, warnings and instructions.
Users
The use of this product is exclusively reserved to authorised,
trained and qualified users. Temporary personnel and
SA-24
voltage
overload
prod. no.
~
0,9 - 1,3
MS-0.9/1.3
400V/3
~
2,2 - 3,2
MS-2.2/3.2
230V/1
~
0,9 - 1,3
MS-0.9/1.3
400V/3
~
1,4 - 2,0
MS-1.4/2.0
400V/3
~
4,5 - 6,3
MS-4.5/6.3
230V/1
~
2,3 - 3,2
MS-2.3/3.2
400V/3
~
4,5 - 6,3
MS-4.5/6.3
400V/3
5°C (41°F)
20°C (68°F)
40°C (104°F)
80%