Setup Instructions; Filling Instructions - Coltene BioSonic UC125H Guide D'utilisation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 14
Owner's Guide
Owner's Guide
An Essential Part of Your Infection
Control System
Congratulations on your purchase of a
BioSonic
Ultrasonic Cleaner- the finest,
®
most efficient and most popular ultrasonic
cleaning system in dentistry.
Developed specifically for the dental
industry, BioSonic units feature unique
product design to optimize time and safety
in the office or laboratory.
BioSonic is a total ultrasonic cleaning
system, with a full line of cleaning
solutions and unit accessories which
provide you with the flexibility to efficiently
clean instruments, prostheses and other
appliances.
What is Ultrasonic Cleaning?
Ultrasonic Cleaning is a process created
by high frequency soundwaves. The
soundwaves, enhanced by specially
formulated cleaning solutions, create
high energy cavitation. During cavitation,
millions of tiny bubbles form and then
collapse or "implode," releasing enormous
amounts of energy and shock waves
which scour the surface of instruments,
appliances and other devices placed in the
cleaning solution. This powerful scouring
action reaches into minute crevices,
which manual brushing cannot reach.
The combination of energy and specially
formulated solutions make ultrasonic
cleaning the most effective method for
removing gross and microscopic debris.
Intended Use: The Biosonic
Ultrasonic Cleaner is intended for cleaning
medical instruments by the emission of
high frequency soundwaves.
I. Unpacking
1. Remove your BioSonic unit from the
shipping container and inspect the unit
for any possible damage which may
have occurred during shipping.
2. Check the serial number of the unit
(found on either the under side or
rear of the unit) with the number on
the shipping carton. If they are not
identical, contact your dealer.
3. Fill out the warranty card and mail to
Coltène/Whaledent Inc. within 10 days
of receipt.
4. Select your desired location for the
cleaner. It should be in close proximity
to a sink or to waste lines to facilitate
draining. The hose supplied with the
unit will allow you to place the unit
on either side of the sink or connect
directly to the waste line.
5. Connect one end of the hose to the
drain valve (Fig. 1) and place the other
end in the sink. If desired, have your
plumber connect the hose directly to
the waste line with the appropriate
fittings.
II. Setup Instructions
1. CONNECT THE DISPLAY. Attach the
connector on the front of the display
module to the connector on the back
top right-hand corner of the unit. Using
the supplied hex L-key tool, install two
screws (included) to secure the Liquid
Crystal Display (LCD).
2. PLUG IN THE UNIT. Attach the
UC125H's electrical cord at the lower
back of the unit and plug into a
three-wire grounded AC outlet (in
accordance with local regulations). It is
recommended that the unit be plugged
into a Ground Fault Circuit Interrupter
(GFCI) outlet.
A. SELECT A LANGUAGE. Using the arrow
keys on the LCD display, select the
language code for your appropriate
region. If you are unsure which code
relates to your office, see the front page
of the Owner's Guide and choose the
language you use in your office. Use the
arrow keys to highlight the appropriate
code. (The code will flash when it is
UC125H
®
selected.) Press ENTER to accept.
3. SET THE CLOCK. Use the arrow keys
to set the time on the UC125H. Four
numbers will appear on the screen. Use
the "+" arrow key to increase the digit;
use the "-" arrow key to decrease the
digit. Press ENTER to accept.
NOTE: Users who select English must
choose AM or PM and press ENTER to
continue.
4. SET THE DATE. Use the arrow keys
to set the date on the UC125H.
"01/01/00" will appear on the screen.
Each number will flash when it is
selected. Use the "+" arrow key to
increase the digit; use the "-" arrow
key to decrease the digit. Press ENTER
to accept.
• US/Date Format (MM/DD/YY)
• International Date Format (DD/MM/YY)
5. SETUP COMPLETE. The display will now
show the message "Setup Complete"
in the language of your choice. Simply
fill the tank of the UC125H with
BioSonic Solution and water. You are
ready to go! Enjoy your UC125H! The
default screen will now display on the
LCD screen, indicating that your unit is
properly programmed.
NOTE: If a mistake is made while
programming the LCD, a user may repeat
this process by pressing and holding the "-"
arrow key for 5 seconds.
MEMORY FEATURE: In the event of a
power failure, your UC125H is equipped
with a back-up power supply that will
retain your programming information.
This supply will be capable of storing user
settings for a minimum of 12 days before it
is again necessary to reprogram the unit.
III. Filling Instructions
1. Insure that the blue drain handle
(Fig. 2) is fully rotated clockwise to the
"Close" position. Fill the unit with warm
water to the fill line indicator (Fig. 3).
2. Pour the required amount of ultrasonic
cleaning solution (either BioSonic
General Purpose UC30, BioSonic
Germicidal Cleaner UC38/UC42 or
BioSonic Enzymatic Ultrasonic Cleaner
UC32) and water into the tank. Press
the solution reset key.
3. Change the solution in the tank
daily, or sooner if it appears soiled or
discolored. When beakers are used,
change the solution in the beaker after
each use.
4. Drain unit by fully rotating the blue
drain handle counter-clockwise to the
"Open" position and allow solution
to empty into sink or waste system.
Rinse tank and fully rotate the blue
drain handle clockwise to the "Close"
position. Never drain tank by manually
discarding solution as this may cause
the unit to stop working properly.
NOTE: Never operate the unit without
solution. Operating a dry tank will void
the warranty. Do not place objects directly
on bottom of tank. Always use accessory
baskets, cassette racks or beakers.
3
3

Publicité

Table des Matières
loading

Table des Matières