2. Connect the cable connectors and ground terminals of the
receptacle box for parallel operation to the generators and secure
the cord clamp to handle.
• Place two generators at least 1 meter (3 feet) away from each
other during parallel operation.
• Route the wire through the handle and clamp it to the handle
using the band.
• Take care not to slacken the wire toward the starter grip side.
• Connect the longer wire to the generator on which the receptacle
box for parallel operation is not installed.
• Do not set the generators with the exhaust side face to face each
other.
CABLE CONNECTORS
GROUND
TERMINAL
BAND
3. Connect the ground terminal of one generator to the ground.
• When an appliance is connected to the ground, connect the
generator to the ground as well.
32
At least 1 m (3 feet)