Honda EU22i Manuel De L'utilisateur page 29

Masquer les pouces Voir aussi pour EU22i:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

NOTE:
• Most appliance motors require more than their rated wattage for
startup. Make sure the electrical rating of the tool or appliance does
not exceed the maximum power rating of the generator.
Maximum power is: 2.2 kVA
• For continuous operation, do not exceed the rated power.
Rated power is: 1.8 kVA
• In either case, the total power requirements (VA) of all appliances
connected must be considered.
• Substantial overloading will switch OFF the AC circuit protector.
Slightly overloading the generator may not switch the AC circuit
protector OFF , but will shorten the service life of the generator.
• The DC receptacle can be used while the AC power is in use (Except
B type).
If you use both at the same time, do not exceed the maximum AC
power.
Maximum AC power: 1.7 kVA