Modifying the water temperature setting

To modify the water temperature just select the MODIFY WATER SET
mode by pressing the button P1.
Then use the buttons 'P1' and 'P2' : the display shows the current
SET temperature status.
When the water temperature has reached the set value,
as a condition also at the same time as that described in par.4.4.1,
the output is automatically brought to the min. value, MODULATION
status.
As for idro model stove, when the water temperature parameter can't
be reached, the activation of led [ A ] starts.
Restart from STANDBY
After shutdown, the stove goes to cooling status, bringing the fume
extractor speed to the set value for brazier cleaning. Relighting occurs
as soon as the room temperature reach the SET value.

Cleaning the brazier

During normal operation in work mode, the 'BRAZIER CLEANING'
mode is activated at fixed intervals for a set duration.
Water heater with heat exchanger quickly
When hot water is required, the display shows the word SCAM HEALTH and LED lights shown from the tap. The
function, however, is only executed if the stove is lit, and has reached a sufficient temperature inside the camera.
In the remaining cases the service is not provided.
4.4.6 Water heater with storage tank
This type of installation requires the use of an external thermostat, which measures the temperature of the water of the
kettle. When the temperature drops below the set temperature of SET in the external thermostat activates the function
of health, the display shows the message of the stove and boiler HEALTH LED lights shown from the tap until the
request is satisfied.
If the stove is in the HOLD step REQUEST automatically turns on and you put in WORK. Once the temperature of
water in the camera work, you turn the water supply to the boiler.
SET When the temperature of the tank is met, the oven converts waste heat to the heating for about 2 minutes and
then, if there is another request, it waits or REQUEST MODULATION, according to the settings ( see prg. 4.6.5).
If the stove is in the OFF state, no lights and does not provide the service.