During stove transport the gaskets in the plumbing system may come loose and/or break, causing water leaks during
normal operation; therefore make sure to check the tightness of the circulating pump and heating chamber connection
rings and vent the residual air during water filling and after the first hours of operation.
Hydraulic diagram - heating pellet stove ref.
Heating pellet stove
Pellet heating
chamber – 2010
Pt=10-14 kW
Int. volume 18.5 lt.
KEY
Drain cock
Pressure sensor / Pressure gauge
Circulating pump
Membrane pressure vessel
Shutoff valve / Cock
Non-return valve
Emergency
2.10
Suitable fire-prevention devices should be arranged for any eventuality.
In case of a fire, proceed as follows:
- Immediately disconnect the plug.
- Extinguish the fire using fire-extinguishers (powder).
- Call the fire department immediately.
- Do not use jets of waters to extinguish the fire.
COLA 10-14kW-06-2010
Thermostat
T > 85°C
Circuit / heating chamber air ven
Safety valve P max 3 bar
Safety sensor T > 85°C
Water temperature sensor
Circuit pressure sensor
Valves to be included in system during
installation – not supplied with the unit
42
Heating DELIVERY
male 3/4"
OVERPRESSURE WATER
DISCHARGE F1/2"
Heating RETURN
3/4"
male
Water supply F1/2"
Pmax 2 bar
Arrangement
PLUMBING CONNECTIONS on back of stove
TERMO FOCUS PLUS acciaio