Troubleshooting
Troubleshooting
Error indicator lights up
Cause:
Remedy:
Error indicator flashing, Acctiva 24-10:
Cause:
Remedy:
Cause:
Remedy:
Fault indicator flashes, Acctiva 12/24-20 selector switch on 24 V:
Cause:
Remedy:
Cause:
Remedy:
Error indicator flashing, Acctiva 12-20:
Cause:
Remedy:
Fault indicator flashes, Acctiva 12/24-20 selector switch on 12 V:
Cause:
Remedy:
Several indicators light up
Cause:
Remedy:
Cause:
Remedy:
Cause:
Remedy:
Cause:
Remedy:
Charging terminals connected to wrong poles
Connect charging terminal poles correctly
Battery voltage not the same as the charging voltage on the charger
Check battery and charger and ensure they are compatible
Battery is exhausted (battery voltage less than 17 V)
Reactivate battery (see section „Charging deep-discharge battery")
Battery voltage not the same as the charging voltage selected
Move selector switch to correct position
Battery is exhausted (battery voltage less than 17 V)
Reactivate battery (see section „Charging deep-discharge battery")
Battery voltage not the same as the charging voltage on the charger
Check battery and charger and ensure they are compatible
Battery voltage not the same as the charging voltage selected
Move selector switch to correct position
Charging terminals not connected to battery
Check connection
Charger lead faulty or break in lead
Check charger lead and replace if necessary
Battery is exhausted
Reactivate battery (see section „Reactivating deep-discharge batte-
ry")
Faulty charger
Have it checked by an authorised workshop