Charging deep-
In the case of deep-discharge batteries (voltage < 2 V), charging must be started manu-
discharge batte-
ally as follows:
ries
1.
2.
3.
4.
5.
6.
7.
8.
9.
10. Adjust the mode according to the battery type and charge the battery
WARNING! Risk of serious damage as the result of
-
incorrectly connected charging terminals. The polarity reversal protection
facility is inoperative in „external power supply/reactivating deep-dischar-
ge batteries" mode.
-
incorrectly set battery voltage.
Connect charging terminals to correct poles and ensure proper electrical
connection to vehicle terminals. Note battery voltage.
CAUTION! Risk of damage when attempting to charge a faulty battery. Before
charging, ensure that the battery to be charged is fully functional.
Unplug machine from the mains
Select „Reactivating deep-discharge batteries" mode (lower switch position)
Connect (+) charging terminal to positive pole (red) on battery
Connect (-) charging terminal to negative pole (black) on the battery, or to vehicle
body (e.g. engine block) in the case of vehicle power supplies.
Acctiva 12/24-20:
Move selector switch to required voltage
The battery is usually reactivated after 30 - 60 s, and can be charged in the relevant
mode
Depending on the charger type, move selector switch to O position or press STOP
button
Unplug machine from the mains
Indicators flash alternately, battery is reacti-
vated
6