18
UK
FITTING THE LIMIT SWITCHES [16]
When the gate is completely open, position the opening limit switch in correspondence with the centre of the pinion.
When the gate is completely close, position the closing limit switch in correspondence with the centre of the pinion.
At first electrical command, check and adjust the positions of the limit switches.
MANUAL UNLOCKING OPERATION
Insert and turn the key included in the package, pull the unlocking lever from left to right up to 90°. Now it is possible to
move the gate manually.
To lock the motor, it is necessary to interrupt the electric line upstream of the operator, position the unlocking lever
again in the initial position and lock the lever with the key
FINAL TESTS
Close the gearmotor casing. Power the system and run a complete opening and closing cycle checking that:
Ÿ the gate moves smoothly;
Ÿ the safety devices function properly;
Ÿ the foundation plate is firmly in place;
Ÿ the gate assembly is in compliance with the current EN 12453 EN 12445 standards;
For further details and information on the reference standards, visit our site: www.gibidi.com
MAINTENANCE
Periodically check the gate structure, in particular:
check perfect functioning of the rails;
Ÿ
check that the rack has not lowered with the weight of the gate, since it would weigh down on the gearmotor. Should
Ÿ
this be the case, raise the rack and retighten the screws lower down in the slot;
every 6 months check good functioning of the safety devices;
Ÿ
unlock the operator and check that there are no points of friction along the entire travel of the gate;
Ÿ
check proper functioning of the unlocking device (see the relative paragraph);
Ÿ
check that there is no dirt or fragments on the pinion.
Ÿ
Ÿ
Gi.Bi.Di. S.r.l. reserves the right to change the technical data without prior notice in relation to product development.