1. General information
Weight
The home owner must ensure that the floor can
withstand the load according to the total weight of the
fireplace. When installing the product on a floating wood
floor, the floor boards underneath the fireplace must be
removed, this to avoid the that the floor boards lock and
crack.
Adjustment
We recommend to stack the surround without glue in
order to adjust the insert prior to perforating the chimney
for the flue connection. Use a spirit level to ensure that
the surround is mounted straight. The insert will expand
with heat and for this reason the surround must not rest
on the insert. (Above the insert there must be a gap
of 3 to 5 mm. Laterally there is no need for gaps, but
between the lower part of the insert and the surround
there must be a gap of at least 2 mm.)
Floor plate
A fireproof floor plate must be put in front of the fireplace
if the floor is of a combustible material.
Acrylic glue
The fireplace is to be assembled using acrylic glue.
Make sure all dust is removed and that the surfaces are
clean. When the fireplace is assembled, use the same
acylic glue for filling joints (FIG Z)
Minor damage
The fireplace can sustain minor damage during
transport and handling.
This can be repaired with acrylic/light filler. For perfect
results, you can fill and sand with a suitable filler. Minor
damage and uneven surfaces can be filled. If the
damage is deep or in the event of significant damage,
you are recommended to fill repeatedly with tile
adhesive or cement putty to avoid sinking. Smooth off
with e.g. a damp sponge or a float.
Fine Fissures
The building material around the fireplace can move.
In new houses in particular, it is common for building
materials to settle substantially in the early years. In
addition, all concrete elements shrink to a decreasing
extent for up to 15 months.
The result is that small cracks may appear in the
concrete/masonry.
Use the fireplace for a few months. If cracks appear,
scrape them out with a screwdriver or similar (to provide
more space for acrylic joint filler). Vacuum the surfaces
to remove any dust.
Inject acrylic joint filler and even it out with a spatula or a
finger wetted with soapy water.
The joint can be painted after a couple of days.
Painting
When the fireplace has been filled/sanded and the
glued joints are dry, the fireplace is ready to be painted.
Use only breathable paint (acrylic) intended for
masonry.
Treatment of marble
Clean the plates with mild soapy water and remove any
residue of spilled glue.
Never use acid/abrasive materials, as this will damage
the surface and polishing.
It is important to use detergent/sealant that is approved
for marble for cleaning and sealing.
Scratches in dark marble can be coloured with a pencil.
A professional stone centre can help you with different
products for surface treatment of the stone.
For your own safety, comply with the assembly
instructions. All safety distances are minimum distances.
Installation of the insert must comply with the rules and
regulations of the country where installed. Nordpeis AS
is not responsible for wrongly assembled inserts.
We accept no liability for typographical errors and
changes.
2. Before Installing a New Fireplace
All our products are tested according to the latest
European requirements and also to the Norwegian
standard NS 3058 and NS 3059, which include particle
tests. However, several European countries have local
regulations for installation of fireplaces, which change
regularly. It is the responsibility of the client that these
regulations are complied with in the country/region
where the fireplace is installed. Nordpeis AS is not
responsible for incorrect installation.
Important to check
(please note that this list is not exhaustive):
•
distance from firebox to combustible/flammable
materials
•
insulation materials/requirements between
fireplace surround and back wall
•
size of floor plates in front of fireplace if required
•
flue connection between firebox and chimney
•
insulation requirements if flue passes through a
flammable wall
Chimney Draft
Compared with older models, the clean burning
fireplaces of today put significantly higher demands
on the chimney. Even the best fireplace will not
work properly if the chimney does not have the right
dimensions or is not in good working order. The draught
is mainly controlled by gas temperature, outside
temperature, air supply as well as the height and inner
diameter of the chimney.
should never be less than that of the flue/chimney
collar.
GB
The diameter of the chimney
3