TAVOLI REFRIGERATI
9.2 Ambient
ENG
Generally, the refrigerators with air condensing units work with a maximum ambient temperature of
32°C. The declared performances are not guaranteed where there are higher temperatures.
NOTES
For a correct installation:
- Check the electrical connections
- Check the absorption machine connected
- Turn on the machine
placing inside the food.
If the appliance has been transported in an improper way (e.g. non-vertical Position or laying on the
back), wait at least 4 hours before switching it on.
Referring to the specific requests of the end user, inform him on the right use of the appliance.
9.3 Cleaning and maintenance
The cleaning and maintenance can be performed by unskilled personnel only by carefully following the
instructions below.
Before starting any operation, disconnect power to the appliance.
Wash the inside of the cell with water and neutral detergent, without water jets or abrasive materials, then
dry thoroughly and place rails and grills as needed. Perform this operation at least every six months.
Set on the desired operating temperature (from +15°C to -2°C for the NORMAL TEMPERATURE (TN)
model and from -18°C t
device (see Part. 15 ) following the instructions.
Clean periodically the condenser using a paint brush or a vacuum cleaner after removing the mains lead
and
taking
Attention! The condenser has sharp edges, wear protective gloves when cleaning.
Do not use the refrigerator to cool hot or just cooked food.
The food inside the cell should be disposed on the grills without exceeding the perimeter in such a way as
to ensure an optimal passage of air
In refrigerators at low temperature (freezer with negative temperature) introduce only products already
frozen. If you need to introduce not frozen food, make sure it does not exceed 10 % of the cell content .
The doors of the appliance must be opened the least number of times possible during the defrosting phase
.
10. Troubleshooting
If there is an abnormal elevation of the internal temperature of the machine, you should check first if:
• the mains lead is securely plugged
• the power is not subject to variations of ± 10%
In case of malfunctioning and when these a.m. data are correct, you should call your supplier.
Give information on the type of machine and its serial number: these data are shown on the label of each
unit.
and allow it to reach the desired temperature before
o -20°C for the LOW TEMPERATURE (BT) model) the digital control
care
not
to
bend
Ed.10/2011
the
aluminum
fins.