Thank you for buying this product, our company is sure that you will be more
than satisfied with the product's performance. The product is supplied with
a "WARNINGS" leaflet and an "INSTRUCTION MANUAL".
These should both be read carefully as they provide important information
about safety, installation, operation and maintenance. This product complies
with the recognised technical standards and safety regulations. We declare
that this product is in conformity with the following Directives: CAN/CSA-
C22.2 No. 247-92 UL Std. No. 325
1) GENERAL OUTLINE
MIZAR UL mod. control unit has been designed to control one single
operator.
2) GENERAL SAFETY
WARNING! An incorrect installation or improper use of the product
can cause damage to persons, animals or things.
The "Warnings" leaflet and "Instruction booklet" supplied with this
product should be read carefully as they provide important information
about safety, installation, use and maintenance.
Scrap packing materials (plastic, cardboard, polystyrene etc) according
to the provisions set out by current standards. Keep nylon or polystyrene
bags out of children's reach.
Keep the instructions together with the technical brochure for future
reference.
This product was exclusively designed and manufactured for the use
specified in the present documentation. Any other use not specified in
this documentation could damage the product and be dangerous.
The Company declines all responsibility for any consequences resulting
from improper use of the product, or use which is different from that
expected and specified in the present documentation.
Do not install the product in explosive atmosphere.
The Company declines all responsibility for any consequences resulting
from failure to observe Good Technical Practice when constructing
closing structures (door, gates etc.), as well as from any deformation
which might occur during use.
Disconnect the electrical power supply before carrying out any work on
the installation. Also disconnect any buffer batteries, if fitted.
Fit an omnipolar or magnetothermal switch on the mains power supply,
having a contact opening distance equal to or greater than 3mm.
Check that a differential switch with a 0.03A threshold is fitted just
before the power supply mains.
Check that earthing is carried out correctly: connect all metal parts for
closure (doors, gates etc.) and all system components provided with an
earth terminal.
The Company declines all responsibility with respect to the automation
safety and correct operation when other manufacturers' components
are used.
Only use original parts for any maintenance or repair operation.
Do not modify the automation components, unless explicitly authorised
by the company.
Instruct the product user about the control systems provided and the
manual opening operation in case of emergency.
Do not allow persons or children to remain in the automation operation
area.
Keep radio control or other control devices out of children's reach, in
order to avoid unintentional automation activation.
The user must avoid any attempt to carry out work or repair on the
automation system, and always request the assistance of qualified
personnel.
Anything which is not expressly provided for in the present instructions,
is not allowed.
INSTALL THE GATE OPERATOR ONLY WHEN:
The operator is appropriate for the construction of the gate and the
usage Class of the gate,
All exposed pinch points are eliminated or guarded,
The operator is intended for installation only on gates used for
vehicles. Pedestrians must supplied with a separate access opening,
The gate must be installed in a location so that enough clearance is
supplied between the gate and adjacent structures when opening
and closing to reduce the risk of entrapment. Swinging gates shall
not open into public access areas,
The gate must be properly installed and work freely in both directions
prior to the installation of the gate operator. Do not over-tighten the
operator clutch or presure relief valve to compensate for a damaged
gate.
INSTALLATION MANUAL
FOR GATE OPENERS WITH HOLD-TO-RUN CONTROL:
The gate operator controls must be placed so that the user has full
view of the gate area when the gate is moving,
A sign with the message "WARNING" must be positioned near the
controls. The characters for the writing should be at least 6.4 mm
high. The following statement should also be indicated: "Moving
Gate Has the Potential of Inflicting Injury or Death - Do Not Start Gate
Unless Path is Clear".
An automatic closing device (such as a timer, loop sensor, or similare
device) shall not be employed
No other activation device shall be connected.
Controls must be far enough from the gate so that the user is prevented from
coming in contact with the gate while operating the controls. controls
intended to be used to reset an operator after 2 sequential activations of the
entrapment protection device or devices must be located in the line-of-sight
of the gate. Outdoor or easly accesible controls shall have a security feature
to prevent unauthorized use.
All warnings signs and placards must be installed where visible in the area
of the gate.
FOR GATE OPENERS PROVIDED WITH SENSOR FOR CONTACT-
FREE DETECTION:
See instructions on the placement of non contact sensor for each
type of application,
Care shall be exercised to reduce the risk of nuisance tripping, such
as when a vheicle, trips the sensor while the gate is still moving, and
One or more non-contact sensor shall be located where the risk of
entrapment or obstruction exist, such as the perimeter reachable by
a moving gate.
FOR GATE OPENERS PROVIDED WITH CONTACT DETECTION
(RUBBER EDGE OR SIMILAR):
On or more contact sensor shall be located at the pinch point of a
vehicular vertical pivot gate.
A hardwired contact sensor shall be located and its wiring arranged
so that the communication between the sensor and the gate operator
is not subjected to mechanical damage.
A wireless contact sensor such as one that transimts radio frequency
(RF) signals the gate operator for entrapment protection functions
shall be located where the transimission of the signals are not
obscrtucted or impeded y building structure, natural landscaping or
similar obstruction. A wireless contact sensor shall function under
the intended end-use conditions.
IMPORTANT SAFETY INSTRUCTIONS
WARNINGS: to reduce the risk of injury or death:
Read and follow all instructions.
Never let children operate or play with gate control. Keep the remote
control away from children.
Always keep people and objects away from the gate. NO ONE
SHOULD
Test the gate operator montly. The gate MUST reverse on contact
with a rigid object activates the non-contact sensor. After adjusting
the force or the limit of travel, reset the gate operator. Failure to adjust
and retest the gate operator properly can increase the risk of injury
or death.
Use the emergency realease only when the gate is not moving.
KEEP GATES PROPERLY MAINTAINED. Read the owners manual.
Have a qualified service person make repairs to gate hardware.
The entrance is for veichles only. Pedestrians must use separate
entrance.
Save these instructions.

3) TECHNICAL SPECIFICATIONS

Power supply: ........................................................ 120V~ ±10% 60Hz (*)
Loadless absorption: .................................................................... 400 mA
Accessory output power: ............................................ 24Vac 200 mA max
Max. motor power absorbed: ........................................................... 500W
Limits switch: ....................................................................... electric switch
Working time: ....................................................... adjustable from 1 to 90s
Control panel dimensions: ........................................................... See fig.1
Case protection: ................................................................................ IP54
Working temperature: ............................................................... -20 +55 °C
(*) Special voltages on request.
CROSS THE PATH OF THE MOVING GATE.