Programming The Special Functions - Reely Black Commando Notice D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

b) Programming the Special Functions
The speed controller is already pre-programmed with the most sensible pre-settings ex works.
If a LiPo battery is used as a drive battery, check the basic settings of the speed controller for whether
undervoltage protection is activated (usually 3.0 V/cell). With the undervoltage recognition deactivated, the
LiPo battery will suffer deep discharge and be destroyed.
If a NiMH driving battery is used, switch off undervoltage recognition or set it to a lower value than for LiPo
batteries.
The programming can be performed very easily via the setup button.
Proceed as follows for programming:
• Switch on the transmitter if you haven't done it already.
• Switch off the speed controller („OFF").
• Keep the setup button (B) next to the on/off switch (A)
pressed and turn the speed controller on („ON").
• Continue to push and hold the setup button (B). Don't
release it.
• The LED at the speed controller flashes red and the
motor emits beeps (continue to keep the setup button
pushed).
• After some time, the LED flashes green (keep the setup button pushed).
The number of green flashes (1x .....5x) shows which setting function is currently selected.
LED flashes green once + 1 beep: Driving function forward/backward or forward only
LED flashes green 2x + 2 beeps: Motor brake
LED flashes green 3x + 3 beeps: Undervoltage recognition for LiPo
LED flashes green 4x + 4 beeps: Start mode when driving off
LED flashes green 5x + 5 beeps: Brake force
The beeps are generated by a short start-up of the brushless motor. These beeps may be very low, depen-
ding on the motor. In this case, observe the LED on the speed controller.
• When the desired setting function that you want to change is displayed (e.g. undervoltage protection, LED flashes
3x green + 3 beeps from the motor), release the setup button.
• Now the LED flashes red again. The number of red flashing signals shows which setting value is active (e.g. under-
voltage protection 3.0 V/cell, red LED flashes 4x briefly red + 4 beeps from the motor).
• Pushing the setup button briefly changes the setting value. The number of red flashing signals of the LED (and the
motor beeps) changes accordingly.
• To leave the setting mode and save programming, switch off the speed controller. If you switch on the speed cont-
roller then, the speed controller is ready for operation with the settings made above.
• If another setting is to be changed, proceed again as described above.