Unit Power-Up; Reset (Load Factory Settings) - gala gar 300 T Manuel Technique

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

0
CODE
SYMBOL
S4
S5
E1
6

UNIT POWER-UP

Set the welding power source ON/OFF switch to "I" to switch on the unit.
300T
The message appears on the following displays: D2
Fx.x
x.x=
software version
First power-up or power-ups following a RESET procedure
The welding power source sets up for welding with the factory presets.
Subsequent power-ups
The welding power source sets up for welding in the latest stable welding configuration that was active at the time of power-off.
7

RESET (LOAD FACTORY SETTINGS)

The reset procedure involves complete restoration of the default values, parameters and memory settings set in the factory.
The reset procedure is useful in the following cases:
− Too many changes made to the welding parameters so user finds it difficult to restore defaults.
− Unidentified software problems that prevent the welding power source from functioning correctly.
A.
PARTIAL RESET
The reset procedure involves restoration of the parameter values and settings, except the following settings:
− settings of the SETUP menu
− saved JOBS
− set language
Set the welding power source ON/OFF switch to "O" to switch the unit off.
Hold down both buttons simultaneously.
S3
S5
Set the welding power source ON/OFF switch to "I" to switch on the unit.
RECALL PARTIAL SETUP ?
Exit without confirmation
Press any button (except S2).
This action will automatically close the menu.
Exit with confirmation
S3
Press the button.
This action will automatically close the menu.
Wait for the memory clear procedure to terminate.
GALA ELECTRONICS 300 T
GALA ELECTRONICS 300 T
GALA ELECTRONICS 300 T
GALA ELECTRONICS 300 T
Hold down the button at the time of power-on to gain access to the SETUP menu.
DC TIG mode: This button selects the torch trigger procedure.
§ 13 page 40
This button selects the welding mode.
Parameters/functions setting: The encoder provides the facility to alter the selected parameter.
Welding: The encoder allows the welding current to be modified.
The message appears on the following displays: D2
DESCRIPTION
SIMULTANEOUS ACTIONS
E E E E
GB
GB
GB
GB
29