Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

0
11

WELDING SETTINGS

A.
ELECTRODE WELDING (MMA)
S5
This button serves to select the following welding mode:
I.
MMA PARAMETERS SETTING (1ST LEVEL)
S3
Press this button to scroll the list of settings to edit.
The selected parameter and its value are shown on the following displays: D2
E1
Using the encoder, edit the value of the selected setting.
The value is saved automatically.
Press any key (except S3) to save the setting and quit the menu.
*1: This parameter is set as a percentage referred to the value of the following parameter: WELDING CURRENT
II.
MMA PARAMETERS SETTING (2ND LEVEL)
S3
Hold down the button for 3 seconds to gain access to the 2nd level menu.
L.2
The message appears on the following displays: D1
L.2= LEVEL.2= 2ND LEVEL MENU
The selected parameter and its value are shown on the following displays: D2
S3
Press this button to scroll the list of settings to edit.
E1
Using the encoder, edit the value of the selected setting.
The value is saved automatically.
Press any key (except S3) to save the setting and quit the menu.
*2: The activation is suitable for the following welding modes:
− MMA
− DC TIG
− AC TIG
Compatible remote control types:
− manual remote controller.
*3: The activation is suitable for the following welding modes:
− MMA
*4: SYN: This code indicates that parameters control is synergic. The optimal value of this parameter is set automatically by the microprocessor
on the basis of the preset welding current value. This value can be displayed but it is not user-adjustable.
III.
MMA SPECIAL FUNCTIONS
S1
Press this button to scroll the list of settings to edit.
The selected parameter and its value are shown on the following displays: D2
E1
Using the encoder, edit the value of the selected setting.
The value is saved automatically.
Press any key (except S1) to save the setting and quit the menu.
GALA ELECTRONICS 300 T
GALA ELECTRONICS 300 T
GALA ELECTRONICS 300 T
GALA ELECTRONICS 300 T
MMA
Tab. 3 - Parameters of the 1st level menu in MMA mode
PARAMETER
MIN
WELDING CURRENT
10 A
MAX WELDING CURRENT
5 A
HOT-START
0 %
ARC-FORCE
0 %
Tab. 4 - Parameters of the 2nd level menu in MMA mode
PARAMETER
MIN
VRD
OFF
LONG ARC VOLTAGE
37
REMOTE CONTROL
OFF
Tab. 5 - Special functions in MMA mode
DEFAULT
MAX
80 A
300 A
80 A
300 A
50 %
100 %
*1
30 %
100 %
*1
DEFAULT
MAX
OFF
ON
*3
SYN
65
*4
OFF
ON
*2
E E E E
GB
GB
GB
GB
36

Publicité

Table des Matières
loading

Table des Matières