V-NOX PUMP INSTALLATION AND MAINTENANCE MANUAL
1- GENERAL
Before installing, carefully read these instructions, which contain the basics for you to get to know the
pump and get the best out of its possible use. If these indications are followed, the components of the
pump will have a long life and hazards will be avoided. This manual must always be kept alongside
the pump. Both the installation and the operation shall meet the safety requirements of the country where the
product is installed. All work will be done with the utmost care and exclusively by qualified personnel with the
requirements of current regulations. Any infringement of the safety regulations, in addition to putting people at
risk and causing damage to the apparatuses, will cause the loss of all right to guarantee. Units will always be
installed vertically.
2- USES
Multi-cellular vertical centrifugal pumps connected by oval flanges. Their projection and manufacturing features
are at the forefront of technology and stand out thanks to the particular services that guarantee maximum
output with total reliability and solidity. They may be used in a wide variety of situations, such as pressure units
for buildings, watering, fire prevention equipment, etc.
3- PUMPED LIQUIDS
The pump is conceived and manufactured to pump clean, pure, non-aggressive liquids.
4- TECHNICAL DATA AND LIMITS OF USE
Pump
- Maximum pumped liquid temperature: +40°C
- Turning speed: 2900 1/min
- Flow: from 1 m
/h to 45 m
3
- Raising speed: up to 160 m
- Maximum ambient temperature: +45°C
- Storage temperature: -10°C +40°C
- Max. relative humidity of air 95%
- Weight: see catalogue for technical data.
Motor
- Supply voltage: 3 x 230-400 V 50/60 Hz up to 4 KW including 3 x 400/690 V 50/60 Hz over 5.5 KW
- Motor protection: IP55
- Isolation class: F
- Absorbed power: see electrical data plate
- Motor construction: According to CEI 2 Standards – 3 issue 1110
If a protection fuse is activated in a three-phase motor, it is best also to replace the
other two fuses along with the one that has blown.
/h depending on the model
3
10
ENGLISH