Movement of auction
Position release
SLOT for inserting control
ROD and SELECTION lock
The standard output of the hot air supply duct is vertical, at the request of the customer can place a rear valve kit
that allows the hot air pipes choked on the left and right channel.
Any modifications must be done by authorised and competent personnel; changes made at random can
cause serious damage to the stove, for which COLA declines any liability.
4.8 Thermostat - external chronothermostat
The unit controls the room temperature by means of its own digital thermostat whose
function is to detect the temperature through a probe and lower the heat output when
the set temperature is reached.
To use an external thermostat, contact an authorised technician and proceed as
follows:
- turn off the power by means of the main switch on the back and detach the power
cable;
- remove the side panel to access the electronic controller;
- referring to the wiring diagram, connect the two wires of thermostat to the respective
board TERM terminals;
- refit everything and check correct operation.
The setting procedure is as follows:
- external thermostat:
- external chronothermostat: SET the temperature to 7° C and disable the chrono
All the menu functions do not change for each of the settings and signalling of the
connection occurs with lighting up of the segment LED on the status bar of the
display.
4.9 Remote control
The remote control works with the settings made in the control panel and allows stove lighting-shutdown, and
adjustment of the required output and temperature.
Since this device transmits through an infrared diode, it must be pointed at the receiver unit in the control panel.
SET the temperature to 7°C;
functions from the menu 03-01.
1st
reference
61
Control
ROD
3rd
reference
2nd
reference
BEAUTY – BEAUTY LUX