Display test
In menu item F, you can set whether a short-time display test is automatically carried
out after power-on.
The display test can be also activated via the serial interface with the following
command:
Display test on: $T1
Display test off: $T0
Display test has priority over blanking and the flash function.
Demo operation mode
If the setting
PLAY
is selected on menu item F, random characters are displayed one
after the other. In this case, no control of the unit is possible.
Blanking
The display can be blanked with the following command:
Blanking on: $B1
Blanking off: $B0
Blanking has priority over the flash function.
Flashing
The flashing function is activated with the following command:
Flashing on: $F1
Flashing off: $F0
If $F1 is transmitted in the data string, the subsequent characters flash until the end
of the data string or until $F0 is transmitted in the data string.
Display brightness
The brightness of the display can be reduced with the following command:
Normal brightness: $L0
Reduced brightness: $L1
44