Replace The Thermal Element; Replacing The Flow Rate Regulator - Franke AQCT0071 Notice De Montage Et De Mise En Service

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

26. Replace the thermal element

Warning!
Set the scald protection after installing the fitting or removing the thermal element.
Failure to observe this instruction can result in injuries due to scalding.
26.1 Remove the shower panel (see
26.2 Remove the temperature selector (see
26.3 Remove the screw (b)
Caution!
Apply the pliers to the area with the largest diameter (a) behind the small sprocket
wheel.
If the sprocket wheel is damaged, the temperature selector cannot be installed.
26.4 Use pliers to remove the thermal element (c).
Important!
Note the installation position of the thermal element.
26.5 Reassemble in reverse order.
26.6 Set the scald protection (see

27. Replacing the flow rate regulator

27.1 Release the grub screw with an Allen key.
27.2 Pull the shower head out of the connection pipe.
27.3 Remove the locking ring on the inside using appropriate pliers for locking rings.
27.4 Pull out the flow rate regulator using flat-nosed pliers.
27.5 Replace the flow rate regulator. Observe the table.
Flow rate
0.15 l/s (orange)
0.20 l/s (red)
Important!
Note the installation position of the flow rate regulator. The struts must point towards
the shower head.
27.6 Insert the flow rate regulator and secure with the locking ring.
a: Struts
b: Direction of flow
27.7 Reassemble in reverse order.
Chapter
21.).
Chapter
Chapter
16.).
Flow rate regulator
FAR-Best.-Nr. 2000104782
FAR-Best.-Nr. 2000104783