27. Replace the thermal element

Warning!
Set the scald protection after installing the fitting or removing the thermal element.
Failure to observe this instruction can result in injuries due to scalding.
27.1 Remove the shower panel (see
27.2 Remove the temperature selector (b) (see
27.3 Remove the screw (b)
Caution!
Apply the pliers to the area with the largest diameter (a) behind the small sprocket
wheel.
If the sprocket wheel is damaged, the temperature selector cannot be installed.
27.4 Use pliers to remove the thermal element (c).
Important!
Note the installation position of the thermal element.
27.5 Reassemble in reverse order.
27.6 Set the scald protection (see

28. Replacing the flow rate regulator

28.1 Undo the grub screw with a hexagonal wrench.
28.2 Pull the shower head out of the connection pipe.
28.3 Remove the locking ring on the inside using appropriate pliers for locking rings.
28.4 Pull out the flow rate regulator using flat-nosed pliers.
28.5 Replace the flow rate regulator. Observe the table.
Important!
Note the installation position of the flow rate regulator. The struts must point towards
the shower head.
28.6 Insert the flow rate regulator and secure with the locking ring.
a: Struts
b: Direction of flow
28.7 Reassemble in reverse order.
Chapter
Chapter
16.).
Flow rate
0.10 l/s (black)
0.15 l/s (orange)
0.20 l/s (red)