29. Troubleshooting

Fault
Water does not flow
Water flows conti-
nuously
Flow time too short or
too long
Water too hot
Water too cold
Water volume too low
Cause
– Water supply interrupted
– Water volume regulator closed
– Power supply interrupted
– Solenoid valve cartridge faulty
– Sensor faulty
– Dirty filters/non-return valves
– Solenoid valve cartridge faulty
– Flow rate regulator in shower head
blocked with scale
– Incorrect flow time setting
– Shower head blocked with scale
– Scald protection set incorrectly
– Thermal element faulty
– Scald protection set incorrectly
– Hot water flow blocked
– Dirty filters/non-return valves
– Hot water supply pressure too low
– Hot water temperature too low
– Thermal element faulty
– Water volume regulator not fully open
– Shower head blocked with scale
– Dirty filters/non-return valves
– Supply pressure too low
- 18 -
Remedy
➯ Restore it
➯ Open it
➯ Restore it
➯ Replace it
➯ Replace it
➯ Clean and
replace if
necessary
➯ Replace it
➯ Clean and
replace if
necessary
➯ Set it
➯ Cleaning
➯ Set it
➯ Replace it
➯ Set it
➯ Open it
➯ Clean and
replace if
necessary
➯ Check it
➯ Increase it
➯ Replace it
➯ Open it
➯ Clean it
➯ Clean and
replace if
necessary
➯ Check it