Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Fault
Thermostat controls
unevenly
If you cannot rectify a fault or if it is not in the list, please contact our customer
service department!

30. Spare parts

Description
1 Cover platelet . . . . . . . . . . . . . . . . . . 2030031443
2 Temperature selector . . . . . . . . . . . . 2030003254
3 Temperature stop . . . . . . . . . . . . . . . 2030003296
4 Thermal element. . . . . . . . . . . . . . . . 2030003300
5 AQUACONTACT sensor. . . . . . . . . . 2030004622
6 Push-on rosette. . . . . . . . . . . . . . . . . 2030022726
7 Lockable
water volume regulator . . . . . . . . 2000104885
8 Shower head spares kit . . . . . . . . . . 2000104849
9 Flow rate regulator
0.15 l/s (9 l/min) . . . . . . . . . . . . . 2000104782
0.20 l/s (12 l/min) . . . . . . . . . . . . 2000104783
10 Solenoid valve cartridge . . . . . . . . . . 2000109499
11 Mounting kit consisting of:
Filters
Non-return valve
O-rings
Seals
Locking rings . . . . . . . . . . . . . . . . 2000104777
Connecting pipe
Hot/cold . . . . . . . . . . . . . . . . . . . . 2000105647
Mixed water . . . . . . . . . . . . . . . . . 2000105648
Cause
– Flow rate regulator in shower head
blocked with scale
– Thermal element dirty
Order No.
- 19 -
Accessories
Zubehör
Battery compartment with battery . . . 2000109466
6 V lithium battery,
Type CRP2. . . . . . . . . . . . . . . . . . 2000104846
Wall-mounted power supply . . . . . . . 2000109417
Extension cable for power supplies
3 m. . . . . . . . . . . . . . . . . . . . . . . . 2000101456
10 m. . . . . . . . . . . . . . . . . . . . . . . 2000101457
Power supply. . . . . . . . . . . . . . . . . . . 2030039477
Extension cable for power supply
5 m. . . . . . . . . . . . . . . . . . . . . . . . 2030043814
Remedy
➯ Clean and
replace if
necessary
➯ Clean it
Order No.
Best.-Nr.

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Aqct007476129822191157612982219085