14. Replace the non-return valve

Warning!
All non-return valves must be replaced at once.
Failure to observe this instruction can result in an increased germ load in the
drinking water and thus pose a health or mortality risk.
14.1 Remove the housing (see
14.2 Undo the grub screws using a hexagonal wrench (a).
14.3 Remove the connection unit (b) from the terminal block (c).
14.4 Use the special wrench (see
guide socket.
Caution!
Note the installation position of the non-return valves.
Important!
The solenoid valve must be connected before the power supply is connected.
14.5 Reassemble in reverse order.

15. Replace solenoid valve cartridge

15.1 Remove the housing (see
15.2 Undo the grub screws using a hexagonal wrench (a).
15.3 Remove the connection unit (b) from the terminal block (c).
15.4 Remove and replace the solenoid valve cartridge (d).
Important!
The solenoid valve must be connected before the power supply is connected.
15.5 Reassemble in reverse order.

16. Replace the battery

16.1 Remove the housing (see
16.2 Lever the battery compartment (a) out of the holder.
16.3 Remove the cover.
16.4 Replace the battery (b).
Caution!
Note the installation position of the battery.
Important!
The solenoid valve must be connected before the power supply is connected.
16.5 Reassemble in reverse order.