commission the device and hold the outdoor station in the desired
position. If necessary, change the position until you have found
the desired view. Remember that the position of the sun changes.
!
The camera has white illumination [22] for the close range. This is
activated by the daylight sensor [24]. You can improve the quality
of the image at night by using additional illumination
!
If you want to install the outdoor station outdoors, it must be
protected against direct rainfall. If operating with the power supply
unit, the unit must be positioned indoors.
!
If operating with the power supply unit, ensure that there is a
suitable option for feeding the power supply cable through (use a
connection cable with a wire cross-section of 0.2 - 0.7 mm²) and, if
required, for the connection cables to the optional door release /
optional button / optional external signal generator at the point of
installation.
!
If you wish to connect a door release, please note that this requires
its own power supply (power consumption: max. 1 A at up to 15 V
AC or DC - see Fig. B). As well as this, please follow the door release
operating instructions.
!
If you wish to connect an external signal generator, please note that
this requires its own power supply (power consumption: max. 1 A at
up to 15 V DC - see Fig. B). As well as this, please follow the signal
generator operating instructions.
Mobile unit:
!
The charging station must be placed on a solid and level surface,
ideally approx. 1-1.5 m above the ground and not directly next to a
wall (optimal reception).
!
Place the charging station in a central position in the dwelling, eg.
in the hallway. Make sure that the chime can be heard throughout
the dwelling.
!
Note that there must be a suitable power outlet within reach of
the mains adapter cable.
Wireless range
By free line of sight between a maximum wireless range of up to 100 -
150 m is possible, within buildings this is reduced to maybe 20 m.
The range cannot be guaranteed as it is dependent on the local conditions.
In order to avoid malfunctions, only one wireless system should be fitted for
each monitoring location/building/home.
A reduction of the range will be caused by:
#
Walls and Floors, in particular those of metal or with metal
reinforcement
#
Sheet metal surfaces e.g. refrigerator, metal shelves
#
Coated windows (eg. those with Insulating glass), radiators, and metal
surfaces
#
Strong electric fields and other radio equipment, eg. microwave ovens,
radio telephones, mobile phones, radio equipment in the 2.4 GHz
range, electric motors and power cables
#
Devices using the same or similar frequency (eg. WLAN-systems)
8. Fitting, connecting and starting up the
28 - GB
door intercom
!
Remove the door intercom [20] from the safety cover [33].
!
Hold the mounting bracket in the desired location, mark the
position of the two fitting holes to be drilled [37] and of a hole for
the cable if necessary [36].
!
Drill the two fitting holes and insert two plugs [40] if required.
!
If necessary, drill a suitable hole through which to feed the cable for
the power supply to the door intercom and any other connection
cables for the optional door release and/or external signal
generator (e.g. an external bell) and/or optional button for opening
the door.
!
Note: A flush-mounted socket in the wall directly above the cable
opening may be helpful to make cable connection easier.
!
Feed all the connection cables required through the drilled hole and
through the cable opening in the protective cover.
!
Fix the mounting bracket to the wall using two screws [39].
!
If batteries are to be used:
!
Release the battery compartment cover [31] screw and lever the
cover from the outdoor station.
!
Insert 2 pcs. LR14 (C), 1,5 V alkaline batteries (not supplied)
into the battery compartment, paying attention to the polarity.
Do not use rechargeable batteries.
!
Refix the cover onto the outdoor station with the screw.
!
Set the energy consumption mode if necessary, as described in
the note in section 11.2 "Switching on the intercom camera
image manually".
!
Carefully lever the plastic cover off the name plate [19], remove the
name plate, label it, re-insert the name plate and replace the
plastic cover over it.
!
If connecting a power supply unit and/or other devices, follow
connection diagram B:
Notes:
#
Only one wire should be inserted into each terminal connection.
A maximum of 2 J-Y(St)Y wires with a diameter of 0.6 twisted
together may, however, be inserted into one terminal. With
three wire ends, a terminal strip or connector must be used to
join the wires before the terminal connection.
#
The exposed wire end (10-12 mm) must be inserted fully into
the terminal connection.
!
To connect a 9-12 V DC power supply unit, attach the two wires
of the supply unit to the GND and DC9-12V power connection
terminals [27].
Note: The door intercom must not be
operated with batteries AND the power supply
unit at the same time!
!
If you are using an optional door release with its own power
supply, connect it with two wires to terminals [27] NO/COM
(max. 1 A at up to 15 V AC/DC). Please also follow the
information provided in the door release operating instructions.
!
If you are using an optional external signal generator with its
own power supply, connect it with the two wires for the signal

Publicité