Wireless modulation
GFSK
Diagonal screen size
2.4" (6.1 cm)
Monitor resolution
240 x 320 pixel
Integrated image storage ring memory, max. 100 snapshots
Operating temperature
± 0° C to + 40° C
Dimensions
53 x 187 x 26 mm
Charging station DVT40L
Power supply
12 V
Power consumption
max. 300 mA
Operating temperature
± 0° C bis + 40° C
Dimensions
80 x 105 x 95 mm
Power supply for charging station
Power supply
230 V ~ AC, 50 Hz
Output
12 V
Application
indoor use only
6. Safety instructions
The following instructions are provided for your safety and satisfaction
during operation of the device. Note that non-observance of these safety
instructions results in significant risks of accident.
Danger!
Failure to comply with the following instructions can
cause fatal injury, damage to health and material damage.
!
Do not leave small children unsupervised with the device,
packaging material or small parts. Otherwise there is a risk of fatal
injury due to choking or suffocation.
!
Do not damage any gas, electricity, water or telecommunication
lines during drilling and fixing work. Otherwise there are dangers of
fire, personal and fatal injury.
!
Treat the cables carefully. Lay these so that they cannot be
damaged and do not present any tripping hazard. Do not pull the
cables over sharp edges and do not crush or crimp them elsewhere.
Otherwise there are dangers of fire, personal and fatal injury.
!
To prevent injuries, secure the door inter- face reliably in
accordance with the installation instructions.
!
Ensure that the devices (apart from the door intercom: IP55) and
the power supply unit do not come into contact with moisture and
do not submerge in water. Otherwise there is a danger of fatal
injury.
!
Only operate the charging station from the supplied power supply.
Before connecting the power supply to the mains, ensure that the
mains current complies with 230 V ~, 50 Hz and is fitted with a
fuse according to regulations.
!
When connecting to the mains, ensure that the door intercom is
supplied with the specified voltage by cable and that the mains
current complies with 230 V ~, 50 Hz and is fitted with a fuse
according to regulations.
!
Perform the connection and installation while the mains power is
disconnected! Otherwise there is a risk of fatal injury due to electric
shock.
!
Do not connect any external voltage to the connection terminals.
"
DC (mains adapter)
"
DC, 500 mA
Otherwise there are dangers of personal and fatal injury and fire.
!
Ensure that the batteries are not short circuited or exposed to fire.
The batteries must not be opened or recharged. Otherwise there is a
risk of fatal injury due to explosion!
!
Leaking or damaged batteries can cause burns by contact with skin.
Handle these using suitable protective gloves.
!
Use only the recommended battery types.
!
Attention! Danger of explosion if the battery is not replaced
correctly. Replace only by the same or equivalent battery type.
!
Insert the batteries with the correct polarity.
!
If the device is not to be used for some period remove the batteries.
!
Do not place the equipment and the batteries near fire, heat or in
areas of high temperature.
!
Protect the equipment and the cables against strong magnetic or
electrical fields and against strong mechanical loads and
vibrations.
!
Only use the equipment with the supplied original parts or original
accessories.
!
Before assembly and use check that all parts are included and that
they are undamaged.
!
Do not connect any damaged device (e.g. damage in transit).
Repairs to the equipment must only be performed by specialists.
!
Remove the mains adapter from the mains outlet when the device is
not required for a longer time.
!
This system transmits and receives radio-frequency signals. If the
system is not installed and used according to the instructions it may
cause interference with other apparatus and just as other apparatus
may interfere with the system. Interference can be reduced by
repositioning the system.
7. Location of equipment
Before fitting the door intercom, you plan where you want it to go. Check
the wireless connection, the picture detail and the function of the
intercom microphone from that location before fitting.
Observe the following points:
Outdoor station:
!
Mount the outdoor station at such a height that visitors can
comfortably reach the doorbell button and that the face of the
person ringing the bell is in the field of view of the camera. Pay
attention to the height of children in doing so. The vertical field of
view of the camera is approx. 96°.
!
The outdoor station is usually installed at the side of the entrance
door. Ensure that the face of a visitor standing in front of the door
can be seen on the monitor. The horizontal field of view of the
camera is approx. 72°.
!
A bracket for 45° corner fitting on the right or left is available as
an option (see "Optional accessories" section).
!
Position the outdoor station so that no direct light or sunshine
falls on the lens. Avoid strong back lighting behind the visitor: in
this case, the person appears darker on the image. Check the
camera image before mounting. Provisionally connect and