TECHNICAL DATA
MODEL
TYPE
OUTPUT
(1)
DELIVERY
(1)
FUEL
- net calorific value
- density
- viscosity at 20 °C
OPERATION
NOZZLES
STANDARD APPLICATIONS
AMBIENT TEMPERATURE
COMBUSTION AIR TEMPERATURE
PUMP
delivery (at 12 bar)
fuel temperature
IN CONFORMITY WITH EEC DIRECTIVES
ACCESSORIES (page 16)
(1) Reference conditions: Ambient temperature 20°C - Barometric pressure 1000 mbar - Altitude 100 m a.s.l.
ELECTRICAL DATA
MOTOR IE1
MODEL
ELECTRICAL SUPPLY
ELECTRIC MOTOR
IGNITION TRANSFORMER
ELECTRICAL POWER CONSUMPTION
ELECTRICAL PROTECTION
MOTOR IE2
MODEL
ELECTRICAL SUPPLY
ELECTRIC MOTOR
IGNITION TRANSFORMER
ELECTRICAL POWER CONSUMPTION
ELECTRICAL PROTECTION
• RADIO DISTURBANCE PROTECTION KIT
If the burner is installed in places particularly subject to radio disturbance (emission of signals exceeding 10 V/m) owing to the presence of an
INVERTER, or in applications where the length of the thermostat connections exceeds 20 metres, a protection kit is available as an interface
between the control box and the burner.
Code
TECHNICAL SPECIFICATIONS
2nd stage
kW
Mcal/h
kg/h
1st stage
kW
Mcal/h
kg/h
kWh/kg
Mcal/kg
3
kg/dm
2
mm
/s max
number
°C
°C max
kg/h
pressure range
bar
°C max
V
200 with neutral ~ +/- 10%
Hz
60 triple-phase
rpm
kW
V
A
V1 - V2
230V - 8kV
I1 - I2
1.8A - 30mA
W max
IP 40
V
200 with neutral ~ +/- 10%
Hz
60 triple-phase
rpm
kW
V
A
V1 - V2
230V - 8kV
I1 - I2
1.8A - 30mA
W max
IP 40
Light oil
11,8
10,2 (10.200 kcal/kg)
0,82 - 0,85
6 (1,5°E - 6 cSt)
- Intermittent (min. 1 stop in 24 hours)
- Two-stage (high and low flame) and single-stage (all - nothing)
2
Boilers: water, steam, diathermic oil
0 - 40
60
2004/108 - 2006/95 - 2006/42
3010386
11
PRESS 4 GJ
609T85
830 - 1660
714 - 1428
70 - 140
415 - 830
357 - 714
35 - 70
244
10 - 21
70
A5-C5-D3-E
PRESS 4 GJ
3525
3
200 - 346
13.3 - 7.7
3.8
PRESS 4 GJ
3525
3
200 - 346
11.6 - 6.7
3.8