2) GENERAL INFORMATION
The LEO B CBB 3 230 L01 control panel comes with standard factory settings. Any
change must be made using the programmer with built-in display or universal
handheld programmer.
Its main features are:
-
Control of 1 single-phase motor
-
Electronic torque control with obstacle detection
-
Separate inputs for safety devices
-
Configurable command inputs
-
ENCODER control input
The board has a terminal strip of the removable kind to make maintenance
or replacement easier. It comes with a series of prewired jumpers to make the
installer's job on site easier.
The jumpers concern terminals: 70-71, 70-72, 70-74, 76-77.
If the above-mentioned terminals are being used, remove the relevant jumpers.
TESTING
The LEO B CBB 3 230 L01 panel controls (checks) the start relays and safety
devices (photocells) before performing each opening and closing cycle.
If there is a malfunction, make sure that the connected devices are working
properly and check the wiring.
Terminal
Definition
L
LINE
N
NEUTRAL
gND
EARTH
10
OPEN1 + CAP1
11
COM1
12
CLOSE1 + CAP1
20
LIgHT 230V
21
AUX 3 - FREE
26
CONTACT (N.O.)
27
(Max. 24V 3W)
40
- REF SWE
41
+ REF SWE
42
A RS485
43
B RS485
50
24V-
51
24V+
52
24 Vsafe+
60
Common
61
IC 1
62
IC 2
63
Common
64
IC 3
65
IC 4
70
Common
71
STOP
72
SAFE 1
73
FAULT 1
74
SAFE 2
75
FAULT 2
76
Common
77
SAFE 3
78
FAULT 3
Y
ANTENNA
#
SHIELD
INSTALLATION MANUAL
Single-phase power supply 230V~ ±10%, 50-60Hz, with earth cable
Motor connection.
OPEN1 + CAP1 Opening Motor and capacitor
COM1 Motor Common
CLOSE1 + CAP1 Closing Motor and capacitor
Flashing light 230V output max. 40W.
Contact N.O. (24V~/3W max).
Can only be used with second channel of radio-receiver plugged into relevant connector.
ENCODER power supply
ENCODER communication
Accessories power supply output.
Tested safety device power supply output (photocell transmitter and safety edge transmitter).
Output active only during operating cycle.
IC 1 and IC 2 inputs common
Configurable command input 1 (N.O.) - Default START E.
START E / START I / OPEN / CLOSE / PED / TIMER / TIMER PED
Refer to the "Command input configuration" table.
Configurable command input 2 (N.O.) - Default PED.
START E / START I / OPEN / CLOSE / PED / TIMER / TIMER PED
Refer to the "Command input configuration" table.
IC 3 and IC 4 inputs common
Configurable command input 3 (N.O.) - Default OPEN.
START E / START I / OPEN / CLOSE / PED / TIMER / TIMER PED
Refer to the "Command input configuration" table.
Configurable command input 4 (N.O.) - Default CLOSE.
START E / START I / OPEN / CLOSE / PED / TIMER / TIMER PED
Refer to the "Command input configuration" table.
STOP, SAFE 1 and SAFE 2 inputs common
The command stops movement. (N.C.)
If not used, leave jumper inserted.
Configurable safety input 1 (N.C.) - Default PHOT.
PHOT / PHOT TEST / PHOT OP / PHOT OP TEST / PHOT CL / PHOT CL TEST / BAR / BAR TEST / BAR 8K2
Refer to the "Safety input configuration" table.
Test input for safety devices connected to SAFE 1.
Configurable safety input 2 (N.C.) - Default BAR.
PHOT / PHOT TEST / PHOT OP / PHOT OP TEST / PHOT CL / PHOT CL TEST / BAR / BAR TEST / BAR 8K2
Refer to the "Safety input configuration" table.
Test input for safety devices connected to SAFE 2.
SAFE 3 input common
Configurable safety input 3 (N.C.) - Default PHOT OP.
PHOT / PHOT TEST / PHOT OP / PHOT OP TEST / PHOT CL / PHOT CL TEST / BAR / BAR TEST
Refer to the "Safety input configuration" table.
Test input for safety devices connected to SAFE 3.
Antenna input.
Use an antenna tuned to 433MHz. Use Rg58 coax cable to connect the Antenna and Receiver. Metal bodies close to the antenna
can interfere with radio reception. If the transmitter's range is limited, move the antenna to a more suitable position.
3) TECHNICAL SPECIFICATIONS
Power supply
Low voltage/mains insulation
Operating temperature range
Thermal overload protection
Dielectric rigidity
Maximum motor power
Accessories power supply
AUX 3
Flashing light
Dimensions
Fuses
Protection rating
(*other voltages to order)
4) TERMINAL BOARD WIRING Fig. B
Description
230V~ ±10% 50Hz*
> 2MOhm 500V
-10 / +55°C
built into motor
mains/LV 3750V~ for 1 minute
750W
24V~ (demand max. 180mA)
24V~safe (demand max. 180mA)
NO contact (24V~/max.3W)
230V~ 40W max
see Fig. A
see Fig. B
IP54
LEO B CBB 3 230 L01-
15