TABLE "A" - PARAMETERS MENU - (PARA )
Parameter
min.
max.
Default
0
120
TCA
partial
1
99
opening
1
99
OP. F ORCE
1
99
CLS. F ORCE
Rev. Dis.
0
200
space
0
250
Maintenance
(*) In the European Union, apply standard EN 12453 for force limitations, and standard EN 12445 for measuring method.
TABLE "B" - LOGIC MENU - (LOGIC)
Logic
Definition
Automatic Closing
TCA
Time
STEP-BY-STEP
Step-by-step
movement
MOVEMNT
Pre-alarm
PRE-ALARM
Deadman
HOLD-TO-RUN
Block pulses during
IBL OPEN
opening
OPEN IN OTHER
Open in other
direction
DIRECT.
INSTALLATION MANUAL
Personal
Definition
10
Automatic closing time [s]
40
Partial opening [%]
Leaf force during opening
80
[%]
Leaf force during closing
80
[%]
0
Reverse disabling space
Programming number of
operations for maintenance
0
threshold
[in hundreds]
Cross out
Default
setting
used
0
0
 
1
0
1
0
 
2
0
0
 
1
0
1
0
 
2
3
0
0
 
1
0
0
 
1
Waiting time before automatic closing.
Adjusts partial opening percentage compared to total opening in "Partial open" mode.
Force exerted by leaf/leaves during opening.
WARNING: It affects impact force directly: make sure that current safety
requirements are met with the set value (*). Install anti-crush safety devices where
necessary.
Force exerted by leaf/leaves during closing.
WARNING: It affects impact force directly: make sure that current safety
requirements are met with the set value (*). Install anti-crush safety devices where
necessary.
Disables obstacle/curb detection near the limit stop in closing
0 = no disabling 200 = disabling Maximum
WARNING: It affects impact force directly: make sure that current safety require-
ments are met with the set value (*). Install anti-crush safety devices where necessary.
Allows you to set a number of operations after which the need for maintenance will be re-
ported on the AUX output configured as Maintenance or Flashing Light and Maintenance .
Logic not enabled
Switches automatic closing on
Inputs configured as Start E, Start I,
Ped operate with 4-step logic.
Inputs configured as Start E, Start I,
Ped operate with 3-step logic. Pulse
during closing reverses movement.
Inputs configured as Start E, Start I,
Ped operate with 2-step logic. Move-
ment reverses with each pulse.
The flashing light comes on at the same time as the motor(s) start.
The flashing light comes on approx. 3 seconds before the motor(s) start.
Pulse operation.
Deadman mode.
Input 64 is configured as OPEN UP.
Input 65 is configured as CLOSE UP.
Operation continues as long as the OPEN UP or CLOSE UP keys are held down.
WARNING: safety devices are not enabled.
Emergency Deadman mode. Usually pulse operation.
If the board fails the safety device tests (photocell or safety edge, Er0x) 3 times in a row, the device is
switched to Deadman mode, which will stay active until the OPEN UP or CLOSE UP keys are released.
Input 64 is configured as OPEN UP.
Input 65 is configured as CLOSE UP.
WARNING: with the device set to Emergency Deadman mode, safety devices are not enabled.
Pulse operation during opening.
Deadman mode during closing.
Input 64 is configured as PULSE OPEN.
Input 65 is configured as CLOSE UP.
WARNING: safety devices are not enabled during closing.
Pulse from inputs configured as Start E, Start I, Ped has effect during opening.
Pulse from inputs configured as Start E, Start I, Ped has no effect during opening.
Standard operating mode (see Fig. D1).
Opens in other direction to standard operating mode (see Fig. D1).
Description
Optional extras
step-by-step mov.
2 STEP
3 STEP
CLOSED
OPENS
OPENS
DURINg
CLOSINg
OPEN
CLOSES
CLOSES
DURINg
STOP + TCA STOP + TCA
OPENINg
AFTER STOP
OPENS
OPENS
LEO B CBB 3 230 L01-
4 STEP
OPENS
STOPS
CLOSES
OPENS
17

Publicité

Table des Matières
loading

Table des Matières