Be sure to read the installation and
operating manual before install-
ing / commissioning. This allows
you to protect yourself and prevent
Scope of supply
zelsius® C5 measuring capsule with calculator
■
1x seal (according to the model)
■
Seal material
■
Wall bracket with fastening materials (only for version with a detachable
■
calculator)
Installation and operating manual, declaration of conformity
■
Technical data
Nominal flow q
p
Maximum flow q
s
Minimum flow q
CMF
i
Minimum flow q
ASF
i
Starting flow horizontally ca.
Temperature range CMF
Temperature range ASF
Minimum pressure
(to avoid cavitation)
Nominal pressure /
peak pressure
IP protection class
Installation position
Heat carrier
Temperature range heat
calculator
Temperature difference range
Ambient class according to
EN 1434
Storage temperature
Interfaces
Ambient conditions /
climatic influencing
(valid for complete compact
meter)
damage. Check the contents of the
packing before installation to be
complete.
m³/h
0.6
m³/h
1.2
l/h
24
l/h
24
l/h
5
°C
10 ≤ Ө q ≤ 90
°C
15 ≤ Ө q ≤ 90
bar
0.3
PS/PN
16/16
54 ( 65 for heating and cooling energy
metering)
horizontal,
horizontal tipped through 90°,
vertical (for stand- or downpipe instal-
lation)
Water
°C
0...105
K
3...80
C
°C
-20...+65
Standard
optical interface (ZVEI, IrDA)
3 pulse inputs/outputs, M-Bus,
optional
wireless M-Bus, LoRaWAN®
Highest permissible ambient tempera-
ture 55 °C
- climatic
Lowest permissible ambient tempera-
ture 5 °C
- mechanical
M1
class
- electro-
magnetic
E1
class
1.5
2.5
3.0
5.0
30 / 60
50 / 100
60
100
5
7
17