UK | Commissioning
PPB 30 RC LEDs
The blue operating
mode LED flashes
once per cycle
The blue operating
mode LED flashes
twice per cycle
The blue operating
mode LED flashes
three times per cycle
The blue operating
mode LED flashes
four times per cycle
LED flashing modes:
50
Parameter
Setting value Setting/Description
Duration of
1
2
intermittent
ventilation/
3
ventilation
level
Sleep
1
function
2
3
Filter run
1
time
2
3
4
Single-room
1
ventilation
unit
2
LED flashing rapidly
5 minutes (red LED 1x)
10 minutes (red LED 2x)
30 minutes (red LED 3x)
Parameters for the duration of the ma-
nual dehumidification function (level 5)
and the duration of the ventilation level
when overriding demand-driven ope-
ration are set here (factory setting
10 minutes).
30 minutes (red LED 1x)
60 minutes (red LED 2x)
90 minutes (red LED 3x)
The duration of the sleep function
(level 0) is parameterised here
(factory setting 60 minutes).
2 months (red LED 1x)
3 months (red LED 2x)
6 months (red LED 3x)
Reset filter runtime (red LED 4x)
The filter running time is parameterised
here (factory setting 6 months).
Operation in pairs
(red LED 1x)
Single-room ventilation unit
(red LED 2x)
If there are reception problems with
the slave or master device, the
PPB 30 RC unit can be enabled as a
single-room ventilation unit.