Mounting / Installation
To make aperture:
• As an installation aid, a drill/punch template at a scale of 1:1 is provided with the device for the purpose
of optimally positioning the device on the control panel.
• With the aid of a spirit level, align the template in the corresponding position on the control panel and
secure in this position. Mark the corner points with a centre punch and drill out with a 6 mm Ø twist
drill. Then saw out the intermediate web with a compass saw. Neatly rework the surfaces until the
dimensions are within the specified tolerances.
• Cleanly deburr edges.
• Before fitting the device into the control panel
aperture, check the position of the seal (must rest
on front shoulder). Working from the outside, fit the
device in the aperture, attach the retaining brackets
and slide back as far as it will go. All four retaining
brackets must be fitted otherwise the enclosure
class IP54 will not be complied with.
• Using a suitable screwdriver, screw the threaded
pins forward until the seal is evenly pressed all
round.
• Check once again that the seal is fitted correctly, if
necessary, release the threaded pins and correct
the position.
4.2.2
Mounting DULCOMETER
NOTE
The device should be mounted in such a position as to facilitate easy read-off and
operation (at eye-level where possible).
The device can be screwed directly onto the wall with the aid of the wall mounting bracket provided
(drilling template enclosed).
Securing material for wall mounting:
• Item (1)
3x button head screws 5 x 45
• Item (2)
3x U-washer 5.3
• Item (3)
3x plastic wall plug d8
The wall mounting bracket (4) can also be used as a drilling aid. For this purpose, set up the mounting
bracket in the corresponding position on the wall.
NOTE
Take particular care when setting up to ensure that sufficient space is available for the
purpose of installing the cables. A space of approx. 120 mm must be left at the top for the
"park position".
Mark and drill the holes. Insert wall plugs (3) and secure mounting bracket with screws (1) and U-washers
(2). Mount device from above on mounting bracket, press slightly against the wall and slide upward by
approx. 4 mm until it is heard to engage in position.
®