Maintenance
Traditional toilet cleaners can be used to clean the toilet and to re-
move scale.
In order to prevent scale deposits from building up in the pump
these must be removed regularly as follows:
• Shut off the water supply by closing the ball valve.
• Pump the toilet empty by pressing the 'EMPTY'
button and holding this in.
• Pour about 1 litre of vinegar or scale remover into the toilet bowl
and let it soak for some hours.
• Open the ball valve again and carry out several cycles in order to
flush the toilet bowl thoroughly and remove all the water used
from the pump.
How often the scale needs to be removed depends on the hardness
of the water, but it should be done at least twice a year.
Do not use products based on sodium (unblocking products) or sol-
vents.
If seawater is used for flushing the toilet should be rinsed through
with fresh water every so often to prevent salt deposits from build-
ing up.
7
Technical details
Voltage
Current
Maximum vertical lift in discharge
Maximum hose length
Pump capacity at discharge height of 3 metres :
Maximum water temperature
Noise level
Protection
Weight
12
110136.02
TMWP
:
12 V
:
25 A
:
:
(7.9 Imp. gallon/min, 9.5 US gallon/min)
(9.5 Imp. gallon/min, 11.3 US gallon/min)
:
:
:
:
• Pump the toilet empty.
EMPTY
3 metres (10 ft)
30 metres (100 ft)
36 litres/min @ 12 V
43 litres/min @ 24 V
35˚C (95˚F)
61 dBA
IP44
18 kg (40 lbs)
TMWS
24 V
15 A
vetus® Electric Marine Toilets TMWP and TMWS