8
Fault Tracing
Fault
(TMWP) The motor runs and the cycle oper-
ates correctly, But the water is pumped out
very slowly, or not at all.
(TMWP) The cycle runs correctly but there is
a large quantity of water left behind in the
toilet after each cycle.
(TMWS) The motor runs but the water in the
toilet bowl is pumped out too slowly or not
at all.
The motor makes a rattling noise.
The cycle is not carried out when the button
or switch is pressed.
The cycle starts but water flows too slowly
into the bowl.
Cycle starts but no water flows into the bowl. The water supply stopcock is turned off.
vetus® Electric Marine Toilets TMWP and TMWS
Ensure that the power supply is switched off during repairs.
Possible cause
The discharge pipe is blocked.
The outlet's shut-off valve is closed.
The discharge pipe is blocked.
The discharge height is too great.
The discharge pipe is blocked.
The discharge height is too great.
The outlet's shut-off valve is closed.
Hard object hitting the revolving blades
There is no power
There is no connection between the switch
and the toilet.
The switch is faulty.
The magnetic valve filter is blocked.
Water pressure too low.
Faulty magnetic valve.
Water pressure too low.
ENGLISH
Solution
Descale the discharge pipe.
Open the shut-off valve.
Descale the discharge pipe.
Modify the installation.
Descale the discharge pipe.
Modify the installation.
Open the shut-off valve.
Remove object.
Check the main switch and fuse
Repair the connection.
Replace the switch.
Clean the filter.
Ensure minimum water pressure is 1.5 bar
(24 psi).
Open the stopcock.
Replace magnetic valve.
Ensure a minimum water pressure of 1.5 bar
(24 psi).
110136.02
13