3.5 Configuration of the controller
Eight preprogrammed charge algorithms, selectable with a rotary
switch:
Pos
Suggested battery type
0
Gel Victron long life (OPzV)
Gel exide A600 (OPzV)
Gel MK
1
Gel Victron deep discharge
Gel Exide A200
AGM Victron deep discharge
Stationary tubular plate
(OPzS)
Rolls Marine (flooded)
Rolls Solar (flooded)
2
Default setting
Gel Victron deep discharge
Gel Exide A200
AGM Victron deep discharge
Stationary tubular plate
(OPzS)
Rolls Marine (flooded)
Rolls Solar (flooded)
3
AGM spiral cell
Stationary tubular plate
(OPzS)
Rolls AGM
4
PzS tubular plate traction
batteries or
OPzS batteries
5
PzS tubular plate traction
batteries or
OPzS batteries
6
PzS tubular plate traction
batteries or
OPzS batteries
Lithium Iron Phosphate
7
(LiFePo
Note: divide all values by two in case of a 12V system and
multiply by two in case of a 48V system.
6
) batteries
4
Absorption
V
28,2
28,6
28,8
29,4
29,8
30,2
30,6
28,4
Float
dV/dT
V
mV/° C
27,6
-32
27,6
-32
27,6
-32
27,6
-32
27,6
-32
27,6
-32
27,6
-32
27,0
0