i
If there is a leak in the hot water pipe
between the appliance and the extraction
points, close the cold water shut-off valve on
the appliance using a slot head screwdriver,
see section 5.6. Have the leaks repaired by
your recognised handicraft business.
5.4
Hot water generation
5.4.1
Drawing hot water
a
Danger!
Risk of scalding!
Hot water temperatures above 60 °C can
cause scalding.
>
Adjust the temperature of the hot water so
that it is just sufficient for your needs.
>
If you open the hot water tap at the extraction point,
such as the wash basin or sink, the gas instantaneous
water heater starts up automatically and provides hot
water.
The green operating LED lights up as long as the
burner is in operation.
i
If the gas instantaneous water heater does
not start when you turn on the tap, check
that the shut-off valve fitted in front of the
tap is completely open or the main switch is
in the on position (I).
i
Also, the strainer in the tap fitting may be
clogged. You can take out the rose to clean it.
If it is clogged with lime scale, we recommend
descaling the rose with a decalcifier such as
vinegar.
The gas instantaneous water heater stops automatically
when you turn off the hot water tap.
Operating manual atmoMAG mini 11-0/0 XI 838291_05
5.4.2 Adjusting the water temperature
Fig. 5.4 Setting the water temperature
The appliance provides water at a constant tempera-
ture, regardless of the quantity drawn and the cold
water intake temperature.
Use the temperature selector (1) to vary the water tem-
perature:
>
Turn the temperature selector clockwise
increase the temperature.
>
Turn the temperature selector anticlockwise
reduce the temperature.
i
The temperature at the individual draw-off
points may differ slightly from the displayed
temperature.
You can also alter the water temperature when drawing
hot water.
Operation 5
1
to
to
INT
9
EN