Power source
Mains voltage
Main fuse
Efficiency
Current MMA DC
Current TIG AC/DC
Permitted load:
MMA/TIG at 100 % duty cycle
MMA/TIG at 60 % duty cycle
MMA/TIG at 35 % duty cycle
Open circuit voltage
TIG start
Upslope
Downslope
Pregas
Postgas
Initial current
Final current
AC Balance
AC Frequency
Hot start MMA
1
Protection class
2
Application class
Standards
Dimensions (W-H-L)
Weight without PFC
Weight with PFC
1
The machine is designed for outdoor applications as it meets the demands of protection class IP23. However, it is a condition
that the machine is placed in an upright position.
S
2
The machine meets the standards which are demanded of machines working in areas where there is an increased risk of elec-
tric shock
TECHNICAL DATA
PILOT 2000
PILOT 2000 PFC
PILOT 2000
PILOT 2000 PFC
TIG 2000 AC/DC
1x230/400 V ±10%
1x230 V ±10%
32 / 16 A
16 A
0.85
5 - 180 A
5 - 200 A
130 A / 135 A
150 A / 155 A
180 A / 200 A
90 V
HF / Liftig
0 - 10 secs
0 - 10 secs
0.1 sec.
3 - 30 secs
0 - 100 %
= initial current
40 - 80 %
70 Hz
50 %
IP 23
S
EN60974
EN50199
21x48x50 cm
29 kg
30 kg
14
TIG 2000 DC
1x230/400 V ±10%
1x230 V ±10%
32 / 16 A
16 A
0.85
5 - 200 A
5 - 200 A
135 A / 140 A
155 A / 160 A
200 A / 200 A
90 V
HF / Liftig
0 - 10 secs
0 - 10 secs
0.1 sec.
3 - 30 secs
0 - 100 %
= initial current
-
-
50 %
IP 23
S
EN60974
EN50199
21x30x50 cm
19 kg
20 kg